On Fri, May 16, 2014 at 12:15 AM, Eduardo Valentin <edubezval@xxxxxxxxx> wrote: > Hello Amit, > > > On Thu, May 08, 2014 at 08:07:57PM +0530, Amit Daniel Kachhap wrote: >> This patch adds notification support for those clients of cpu_cooling >> APIs which may want to do something interesting after receiving these >> cpu_cooling events. The notifier structure passed is of both Set/Get type. >> The notfications events can be of type, >> 1. CPU_COOLING_SET_STATE_PRE >> 2. CPU_COOLING_SET_STATE_POST >> 3. CPU_COOLING_GET_CUR_STATE >> 4. CPU_COOLING_GET_MAX_STATE > > What do you think about expanding this feature to all cooling devices? > > I mean, why should we restrict to cpu(freq) cooling? nice suggestion. Sure will check its feasibility. > > The clock cooling device I posted (and that I plan to merge soon) should > also benefit of this infrastructure. The clock cooling is for the > context of other processing units, that do not benefit of cpufreq. ok let me check them. > > >> >> The advantages of these notfications is to differentiate between different >> P states in the cpufreq table and the cooling states. The clients of these >> events may group few P states into 1 cooling states. Also some more cooling >> states can be enabled when the maximum of P state is reached. Post notifications >> can be used for those cases. >> >> Signed-off-by: Amit Daniel Kachhap <amit.daniel@xxxxxxxxxxx> >> --- >> drivers/thermal/cpu_cooling.c | 99 +++++++++++++++++++++++++++++++++++++++- >> include/linux/cpu_cooling.h | 55 +++++++++++++++++++++++ >> 2 files changed, 151 insertions(+), 3 deletions(-) >> >> diff --git a/drivers/thermal/cpu_cooling.c b/drivers/thermal/cpu_cooling.c >> index 21f44d4..e2aeb36 100644 >> --- a/drivers/thermal/cpu_cooling.c >> +++ b/drivers/thermal/cpu_cooling.c >> @@ -50,6 +50,7 @@ struct cpufreq_cooling_device { >> unsigned int cpufreq_state; >> unsigned int cpufreq_val; >> struct cpumask allowed_cpus; >> + struct cpufreq_cooling_status request_status; >> struct list_head node; >> }; >> static DEFINE_IDR(cpufreq_idr); >> @@ -59,6 +60,8 @@ static DEFINE_MUTEX(cooling_cpufreq_lock); >> #define NOTIFY_INVALID NULL >> static struct cpufreq_cooling_device *notify_device; >> >> +/* Notfier list to validates/updates the cpufreq cooling states */ >> +static BLOCKING_NOTIFIER_HEAD(cpufreq_cooling_state_notifier_list); >> /* A list to hold all the cpufreq cooling devices registered */ >> static LIST_HEAD(cpufreq_cooling_list); >> >> @@ -266,6 +269,21 @@ static unsigned int get_cpu_frequency(unsigned int cpu, unsigned long level) >> return freq; >> } >> >> +static int >> +cpufreq_cooling_notify_states(struct cpufreq_cooling_status *request, >> + enum cpu_cooling_state_ops op) >> +{ >> + /* Invoke the notifiers which have registered for this state change */ >> + if (op == CPU_COOLING_SET_STATE_PRE || >> + op == CPU_COOLING_SET_STATE_POST || >> + op == CPU_COOLING_GET_MAX_STATE || >> + op == CPU_COOLING_GET_CUR_STATE) { >> + blocking_notifier_call_chain( >> + &cpufreq_cooling_state_notifier_list, op, request); >> + } >> + return 0; >> +} >> + >> /** >> * cpufreq_apply_cooling - function to apply frequency clipping. >> * @cpufreq_device: cpufreq_cooling_device pointer containing frequency >> @@ -285,9 +303,18 @@ static int cpufreq_apply_cooling(struct cpufreq_cooling_device *cpufreq_device, >> struct cpumask *mask = &cpufreq_device->allowed_cpus; >> unsigned int cpu = cpumask_any(mask); >> >> + cpufreq_device->request_status.cur_state = >> + cpufreq_device->cpufreq_state; >> + cpufreq_device->request_status.new_state = cooling_state; >> + >> + cpufreq_cooling_notify_states(&cpufreq_device->request_status, >> + CPU_COOLING_SET_STATE_PRE); >> + > > Can a listener block/abort/postpone a state transition? > >> + cooling_state = cpufreq_device->request_status.new_state; >> > > So you are proposing listeners can have control on target cpufreq state, > right? Or did I get it wrong? > > I think we should have this better documented. Besides, if that is the > case, what happens if we have several listeners? > >> /* Check if the old cooling action is same as new cooling action */ >> - if (cpufreq_device->cpufreq_state == cooling_state) >> + if (cpufreq_device->cpufreq_state == >> + cpufreq_device->request_status.new_state) >> return 0; >> >> clip_freq = get_cpu_frequency(cpu, cooling_state); >> @@ -304,7 +331,8 @@ static int cpufreq_apply_cooling(struct cpufreq_cooling_device *cpufreq_device, >> } >> >> notify_device = NOTIFY_INVALID; >> - >> + cpufreq_cooling_notify_states(&cpufreq_device->request_status, >> + CPU_COOLING_SET_STATE_POST); >> return 0; >> } >> >> @@ -383,6 +411,11 @@ static int cpufreq_get_max_state(struct thermal_cooling_device *cdev, >> if (count > 0) >> *state = count; >> >> + cpufreq_device->request_status.max_state = count; >> + cpufreq_cooling_notify_states(&cpufreq_device->request_status, >> + CPU_COOLING_GET_MAX_STATE); >> + *state = cpufreq_device->request_status.max_state; >> + > > same question here, who determines the priorities when several listeners > are present in the system? > >> return ret; >> } >> >> @@ -410,8 +443,12 @@ static int cpufreq_get_cur_state(struct thermal_cooling_device *cdev, >> /* Cooling device pointer not found */ >> return -EINVAL; >> } >> + cpufreq_device->request_status.cur_state = >> + cpufreq_device->cpufreq_state; >> + cpufreq_cooling_notify_states(&cpufreq_device->request_status, >> + CPU_COOLING_GET_CUR_STATE); >> > > ditto. > >> - *state = cpufreq_device->cpufreq_state; >> + *state = cpufreq_device->request_status.cur_state; >> >> return 0; >> } >> @@ -520,6 +557,7 @@ __cpufreq_cooling_register(struct device_node *np, >> } >> cpufreq_dev->cool_dev = cool_dev; >> cpufreq_dev->cpufreq_state = 0; >> + cpufreq_dev->request_status.devdata = devdata; >> mutex_lock(&cooling_cpufreq_lock); >> >> /* Register the notifier for first cpufreq cooling device */ >> @@ -614,3 +652,58 @@ void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev) >> kfree(cpufreq_dev); >> } >> EXPORT_SYMBOL_GPL(cpufreq_cooling_unregister); >> + >> +/** >> + * cpufreq_cooling_register_notifier - register a driver with cpufreq cooling. >> + * @nb: notifier function to register. >> + * @list: CPU_COOLING_STATE_NOTIFIER type. >> + * >> + * Add a driver to receive cpufreq cooling notifications like current state, >> + * max state and set state. The drivers after reading the events can perform >> + * some mapping between the P states and cooling states like grouping some P >> + * states into 1 cooling state. >> + * >> + * Return: 0 (success) >> + */ >> +int cpufreq_cooling_register_notifier(struct notifier_block *nb, >> + unsigned int list) >> +{ >> + int ret = 0; >> + switch (list) { >> + case CPU_COOLING_STATE_NOTIFIER: >> + ret = blocking_notifier_chain_register( >> + &cpufreq_cooling_state_notifier_list, nb); >> + break; >> + default: >> + ret = -EINVAL; >> + } >> + return ret; >> +} >> +EXPORT_SYMBOL_GPL(cpufreq_cooling_register_notifier); >> + >> +/** >> + * cpufreq_cooling_unregister_notifier - unregisters a driver with cpufreq >> + * cooling. >> + * @nb: notifier function to unregister. >> + * @list: CPU_COOLING_STATE_NOTIFIER type. >> + * >> + * Removes a driver to receive further cpufreq cooling notifications. >> + * >> + * Return: 0 (success) >> + */ >> +int cpufreq_cooling_unregister_notifier(struct notifier_block *nb, >> + unsigned int list) >> +{ >> + int ret = 0; >> + switch (list) { >> + case CPU_COOLING_STATE_NOTIFIER: >> + ret = blocking_notifier_chain_unregister( >> + &cpufreq_cooling_state_notifier_list, nb); >> + break; >> + default: >> + ret = -EINVAL; >> + } >> + >> + return ret; >> +} >> +EXPORT_SYMBOL_GPL(cpufreq_cooling_unregister_notifier); > > The exported symbols must be documented under Documentation/ too. > >> diff --git a/include/linux/cpu_cooling.h b/include/linux/cpu_cooling.h >> index aaef7d8..f786935 100644 >> --- a/include/linux/cpu_cooling.h >> +++ b/include/linux/cpu_cooling.h >> @@ -28,6 +28,22 @@ >> #include <linux/thermal.h> >> #include <linux/cpumask.h> >> >> +#define CPU_COOLING_STATE_NOTIFIER (0) >> + >> +enum cpu_cooling_state_ops { >> + CPU_COOLING_SET_STATE_PRE, >> + CPU_COOLING_SET_STATE_POST, >> + CPU_COOLING_GET_CUR_STATE, >> + CPU_COOLING_GET_MAX_STATE, >> +}; >> + >> +struct cpufreq_cooling_status { >> + unsigned long cur_state; >> + unsigned long new_state; >> + unsigned long max_state; >> + void *devdata; >> +}; >> + >> #ifdef CONFIG_CPU_THERMAL >> /** >> * cpufreq_cooling_register - function to create cpufreq cooling device. >> @@ -62,6 +78,34 @@ of_cpufreq_cooling_register(struct device_node *np, >> void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev); >> >> unsigned long cpufreq_cooling_get_level(unsigned int cpu, unsigned int freq); >> + >> +/** >> + * cpufreq_cooling_register_notifier - register a driver with cpufreq cooling. >> + * @nb: notifier function to register. >> + * @list: CPU_COOLING_STATE_NOTIFIER type. >> + * >> + * Add a driver to receive cpufreq cooling notifications like current state, >> + * max state and set state. The drivers after reading the events can perform >> + * some mapping between the P states and cooling states like grouping some P >> + * states into 1 cooling state. >> + * >> + * Return: 0 (success) >> + */ >> +int cpufreq_cooling_register_notifier(struct notifier_block *nb, >> + unsigned int list); >> + >> +/** >> + * cpufreq_cooling_unregister_notifier - unregisters a driver with cpufreq >> + * cooling. >> + * @nb: notifier function to unregister. >> + * @list: CPU_COOLING_STATE_NOTIFIER type. >> + * >> + * Removes a driver to receive further cpufreq cooling notifications. >> + * >> + * Return: 0 (success) >> + */ >> +int cpufreq_cooling_unregister_notifier(struct notifier_block *nb, >> + unsigned int list); >> #else /* !CONFIG_CPU_THERMAL */ >> static inline struct thermal_cooling_device * >> cpufreq_cooling_register(const struct cpumask *clip_cpus, void *devdata) >> @@ -84,6 +128,17 @@ unsigned long cpufreq_cooling_get_level(unsigned int cpu, unsigned int freq) >> { >> return THERMAL_CSTATE_INVALID; >> } >> +static inline int >> +cpufreq_cooling_register_notifier(struct notifier_block *nb, unsigned int list) >> +{ >> + return 0; >> +} >> +static inline int >> +cpufreq_cooling_unregister_notifier(struct notifier_block *nb, >> + unsigned int list) >> +{ >> + return 0; >> +} >> #endif /* CONFIG_CPU_THERMAL */ >> >> #endif /* __CPU_COOLING_H__ */ >> -- >> 1.7.1 >> >> -- >> To unsubscribe from this list: send the line "unsubscribe linux-kernel" in >> the body of a message to majordomo@xxxxxxxxxxxxxxx >> More majordomo info at http://vger.kernel.org/majordomo-info.html >> Please read the FAQ at http://www.tux.org/lkml/ -- To unsubscribe from this list: send the line "unsubscribe linux-acpi" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html