This patch moves the thermal_instance structure to thermal.h so that thermal management files (other than thermal_sys.c) can also access it. Signed-off-by: Durgadoss R <durgadoss.r@xxxxxxxxx> --- drivers/thermal/thermal_sys.c | 21 --------------------- include/linux/thermal.h | 23 +++++++++++++++++++++++ 2 files changed, 23 insertions(+), 21 deletions(-) diff --git a/drivers/thermal/thermal_sys.c b/drivers/thermal/thermal_sys.c index 5be8728..a0e20f9 100644 --- a/drivers/thermal/thermal_sys.c +++ b/drivers/thermal/thermal_sys.c @@ -41,27 +41,6 @@ MODULE_AUTHOR("Zhang Rui"); MODULE_DESCRIPTION("Generic thermal management sysfs support"); MODULE_LICENSE("GPL"); -#define THERMAL_NO_TARGET -1UL -/* - * This structure is used to describe the behavior of - * a certain cooling device on a certain trip point - * in a certain thermal zone - */ -struct thermal_instance { - int id; - char name[THERMAL_NAME_LENGTH]; - struct thermal_zone_device *tz; - struct thermal_cooling_device *cdev; - int trip; - unsigned long upper; /* Highest cooling state for this trip point */ - unsigned long lower; /* Lowest cooling state for this trip point */ - unsigned long target; /* expected cooling state */ - char attr_name[THERMAL_NAME_LENGTH]; - struct device_attribute attr; - struct list_head tz_node; /* node in tz->thermal_instances */ - struct list_head cdev_node; /* node in cdev->thermal_instances */ -}; - static DEFINE_IDR(thermal_tz_idr); static DEFINE_IDR(thermal_cdev_idr); static DEFINE_MUTEX(thermal_idr_lock); diff --git a/include/linux/thermal.h b/include/linux/thermal.h index 8611e3e..f25df23 100644 --- a/include/linux/thermal.h +++ b/include/linux/thermal.h @@ -33,6 +33,9 @@ #define THERMAL_MAX_TRIPS 12 #define THERMAL_NAME_LENGTH 20 +/* Initial state of a cooling device during binding */ +#define THERMAL_NO_TARGET -1UL + /* No upper/lower limit requirement */ #define THERMAL_NO_LIMIT -1UL @@ -164,6 +167,26 @@ struct thermal_zone_device { struct delayed_work poll_queue; }; +/* + * This structure is used to describe the behavior of + * a certain cooling device on a certain trip point + * in a certain thermal zone + */ +struct thermal_instance { + int id; + char name[THERMAL_NAME_LENGTH]; + struct thermal_zone_device *tz; + struct thermal_cooling_device *cdev; + int trip; + unsigned long upper; /* Highest cooling state for this trip point */ + unsigned long lower; /* Lowest cooling state for this trip point */ + unsigned long target; /* expected cooling state */ + char attr_name[THERMAL_NAME_LENGTH]; + struct device_attribute attr; + struct list_head tz_node; /* node in tz->thermal_instances */ + struct list_head cdev_node; /* node in cdev->thermal_instances */ +}; + struct thermal_genl_event { u32 orig; enum events event; -- 1.7.9.5 -- To unsubscribe from this list: send the line "unsubscribe linux-acpi" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html