From: Alexey Starikovskiy <aystarik@xxxxxxxxx> ACPI battery interface reports its state either in mW or in mA, and discharge rate in your case is reported in mW. power_supply interface does not have such a parameter, so current_now parameter is used for all cases. But in case of mW, reported discharge should be converted into mA. Signed-off-by: Alexey Starikovskiy <astarikovskiy@xxxxxxx> Tested-by: Ferenc Wagner <wferi@xxxxxxx> Signed-off-by: Len Brown <len.brown@xxxxxxxxx> --- drivers/acpi/battery.c | 9 +++++++++ 1 files changed, 9 insertions(+), 0 deletions(-) diff --git a/drivers/acpi/battery.c b/drivers/acpi/battery.c index 1423b0c..a0a178d 100644 --- a/drivers/acpi/battery.c +++ b/drivers/acpi/battery.c @@ -174,6 +174,15 @@ static int acpi_battery_get_property(struct power_supply *psy, break; case POWER_SUPPLY_PROP_CURRENT_NOW: val->intval = battery->current_now * 1000; + /* if power units are mW, convert to mA by + dividing by current voltage (mV/1000) */ + if (!battery->power_unit) { + if (battery->voltage_now) { + val->intval /= battery->voltage_now; + val->intval *= 1000; + } else + val->intval = -1; + } break; case POWER_SUPPLY_PROP_CHARGE_FULL_DESIGN: case POWER_SUPPLY_PROP_ENERGY_FULL_DESIGN: -- 1.5.6.5 -- To unsubscribe from this list: send the line "unsubscribe linux-acpi" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html