[PATCH v3 2/3] ACPI: EC: Fix oops when removing custom query handlers

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



When removing custom query handlers, the handler might still
be used inside the EC query workqueue, causing a kernel oops
if the module holding the callback function was already unloaded.

Fix this by flushing the EC query workqueue when removing
custom query handlers.

Tested on a Acer Travelmate 4002WLMi

Signed-off-by: Armin Wolf <W_Armin@xxxxxx>
---
 drivers/acpi/ec.c | 1 +
 1 file changed, 1 insertion(+)

diff --git a/drivers/acpi/ec.c b/drivers/acpi/ec.c
index f84905dbd8ca..4ae017391533 100644
--- a/drivers/acpi/ec.c
+++ b/drivers/acpi/ec.c
@@ -1132,6 +1132,7 @@ static void acpi_ec_remove_query_handlers(struct acpi_ec *ec,
 void acpi_ec_remove_query_handler(struct acpi_ec *ec, u8 query_bit)
 {
 	acpi_ec_remove_query_handlers(ec, false, query_bit);
+	flush_workqueue(ec_query_wq);
 }
 EXPORT_SYMBOL_GPL(acpi_ec_remove_query_handler);

--
2.30.2




[Index of Archives]     [Linux IBM ACPI]     [Linux Power Management]     [Linux Kernel]     [Linux Laptop]     [Kernel Newbies]     [Share Photos]     [Security]     [Netfilter]     [Bugtraq]     [Yosemite News]     [MIPS Linux]     [ARM Linux]     [Linux Security]     [Linux RAID]     [Samba]     [Video 4 Linux]     [Device Mapper]     [Linux Resources]