On Mon, Dec 20, 2021 at 10:05:33PM +0100, Clément Léger wrote: > nargs_prop refers to a property located in the reference that is found > within the nargs property. Use the correct reference node in call to > property_entry_read_int_array() to retrieve the correct nargs value. > > Fixes: b06184acf751 ("software node: Add software_node_get_reference_args()") > Signed-off-by: Clément Léger <clement.leger@xxxxxxxxxxx> Thank you (and thanks to Andy for cc'ing me). Reviewed-by: Sakari Ailus <sakari.ailus@xxxxxxxxxxxxxxx> > --- > drivers/base/swnode.c | 2 +- > 1 file changed, 1 insertion(+), 1 deletion(-) > > diff --git a/drivers/base/swnode.c b/drivers/base/swnode.c > index 4debcea4fb12..0a482212c7e8 100644 > --- a/drivers/base/swnode.c > +++ b/drivers/base/swnode.c > @@ -529,7 +529,7 @@ software_node_get_reference_args(const struct fwnode_handle *fwnode, > return -ENOENT; > > if (nargs_prop) { > - error = property_entry_read_int_array(swnode->node->properties, > + error = property_entry_read_int_array(ref->node->properties, > nargs_prop, sizeof(u32), > &nargs_prop_val, 1); > if (error) -- Sakari Ailus