DSA supports connecting to a phy-handle, and has a fallback to a non-OF based method of connecting to an internal PHY on the switch's own MDIO bus, if no phy-handle and no fixed-link nodes were present. The -ENODEV error code from the first attempt (phylink_of_phy_connect) is what triggers the second attempt (phylink_connect_phy). However, when the first attempt returns a different error code than -ENODEV, this results in an unbalance of calls to phylink_create and phylink_destroy by the time we exit the function. The phylink instance has leaked. There are many other error codes that can be returned by phylink_of_phy_connect. For example, phylink_validate returns -EINVAL. So this is a practical issue too. Fixes: aab9c4067d23 ("net: dsa: Plug in PHYLINK support") Signed-off-by: Vladimir Oltean <vladimir.oltean@xxxxxxx> --- I know, I will send this bug fix to "net" too, this is provided just for testing purposes, and for the completeness of the patch set. net/dsa/slave.c | 12 +++++------- 1 file changed, 5 insertions(+), 7 deletions(-) diff --git a/net/dsa/slave.c b/net/dsa/slave.c index a7a114b9cb77..8a395290267c 100644 --- a/net/dsa/slave.c +++ b/net/dsa/slave.c @@ -1856,13 +1856,11 @@ static int dsa_slave_phy_setup(struct net_device *slave_dev) * use the switch internal MDIO bus instead */ ret = dsa_slave_phy_connect(slave_dev, dp->index, phy_flags); - if (ret) { - netdev_err(slave_dev, - "failed to connect to port %d: %d\n", - dp->index, ret); - phylink_destroy(dp->pl); - return ret; - } + } + if (ret) { + netdev_err(slave_dev, "failed to connect to PHY: %pe\n", + ERR_PTR(ret)); + phylink_destroy(dp->pl); } return ret; -- 2.25.1