ACPI: thinkpad-acpi: make EC-based thermal readings non-experimental

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Reading the 16 thermal sensors directly from the EC has been stable for
about one year, in all supported ThinkPad models.  Remove its
"experimental" label.

Signed-off-by: Henrique de Moraes Holschuh <hmh@xxxxxxxxxx>
---
 Documentation/thinkpad-acpi.txt |   18 +++++-------------
 drivers/misc/thinkpad_acpi.c    |    2 +-
 2 files changed, 6 insertions(+), 14 deletions(-)

diff --git a/Documentation/thinkpad-acpi.txt b/Documentation/thinkpad-acpi.txt
index 5d827de..3eb949e 100644
--- a/Documentation/thinkpad-acpi.txt
+++ b/Documentation/thinkpad-acpi.txt
@@ -710,23 +710,15 @@ Temperature sensors
 procfs: /proc/acpi/ibm/thermal
 sysfs device attributes: (hwmon) temp*_input
 
-Most ThinkPads include six or more separate temperature sensors but
-only expose the CPU temperature through the standard ACPI methods.
-This feature shows readings from up to eight different sensors on older
-ThinkPads, and it has experimental support for up to sixteen different
-sensors on newer ThinkPads.
-
-EXPERIMENTAL: The 16-sensors feature is marked EXPERIMENTAL because the
-implementation directly accesses hardware registers and may not work as
-expected. USE WITH CAUTION! To use this feature, you need to supply the
-experimental=1 parameter when loading the module.  When EXPERIMENTAL
-mode is enabled, reading the first 8 sensors on newer ThinkPads will
-also use an new experimental thermal sensor access mode.
+Most ThinkPads include six or more separate temperature sensors but only
+expose the CPU temperature through the standard ACPI methods.  This
+feature shows readings from up to eight different sensors on older
+ThinkPads, and up to sixteen different sensors on newer ThinkPads.
 
 For example, on the X40, a typical output may be:
 temperatures:   42 42 45 41 36 -128 33 -128
 
-EXPERIMENTAL: On the T43/p, a typical output may be:
+On the T43/p, a typical output may be:
 temperatures:   48 48 36 52 38 -128 31 -128 48 52 48 -128 -128 -128 -128 -128
 
 The mapping of thermal sensors to physical locations varies depending on
diff --git a/drivers/misc/thinkpad_acpi.c b/drivers/misc/thinkpad_acpi.c
index edae74f..2a26941 100644
--- a/drivers/misc/thinkpad_acpi.c
+++ b/drivers/misc/thinkpad_acpi.c
@@ -2709,7 +2709,7 @@ static int __init thermal_init(struct ibm_init_struct *iibm)
 
 	acpi_tmp7 = acpi_evalf(ec_handle, NULL, "TMP7", "qv");
 
-	if (thinkpad_id.ec_model && experimental) {
+	if (thinkpad_id.ec_model) {
 		/*
 		 * Direct EC access mode: sensors at registers
 		 * 0x78-0x7F, 0xC0-0xC7.  Registers return 0x00 for
-- 
1.5.2.1

-
To unsubscribe from this list: send the line "unsubscribe linux-acpi" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at  http://vger.kernel.org/majordomo-info.html

[Index of Archives]     [Linux IBM ACPI]     [Linux Power Management]     [Linux Kernel]     [Linux Laptop]     [Kernel Newbies]     [Share Photos]     [Security]     [Netfilter]     [Bugtraq]     [Yosemite News]     [MIPS Linux]     [ARM Linux]     [Linux Security]     [Linux RAID]     [Samba]     [Video 4 Linux]     [Device Mapper]     [Linux Resources]

  Powered by Linux