For these legacy Intel CPUs without clflush/clflushopt support, there is on way to force to trigger a LLC miss and the measured llc misses is possible to be 0. Thus adjust the lower boundary of llc-misses event to 0 to avoid possible false positive. Signed-off-by: Dapeng Mi <dapeng1.mi@xxxxxxxxxxxxxxx> --- x86/pmu.c | 10 ++++++++++ 1 file changed, 10 insertions(+) diff --git a/x86/pmu.c b/x86/pmu.c index 799d8d5c..c9c5fc19 100644 --- a/x86/pmu.c +++ b/x86/pmu.c @@ -82,6 +82,7 @@ struct pmu_event { enum { INTEL_INSTRUCTIONS_IDX = 1, INTEL_REF_CYCLES_IDX = 2, + INTEL_LLC_MISSES_IDX = 4, INTEL_BRANCHES_IDX = 5, }; @@ -877,6 +878,15 @@ int main(int ac, char **av) gp_events_size = sizeof(intel_gp_events)/sizeof(intel_gp_events[0]); instruction_idx = INTEL_INSTRUCTIONS_IDX; branch_idx = INTEL_BRANCHES_IDX; + + /* + * For legacy Intel CPUS without clflush/clflushopt support, + * there is no way to force to trigger a LLC miss, thus set + * the minimum value to 0 to avoid false positives. + */ + if (!this_cpu_has(X86_FEATURE_CLFLUSH)) + gp_events[INTEL_LLC_MISSES_IDX].min = 0; + report_prefix_push("Intel"); set_ref_cycle_expectations(); } else { -- 2.40.1