On Wed, Feb 08 2023 at 00:09, Brian Gerst wrote: > On Tue, Feb 7, 2023 at 6:10 PM Usama Arif <usama.arif@xxxxxxxxxxxxx> wrote: >> Introduce a global variable 'smpboot_control' indicating to the AP how >> it should find its APIC ID. For a serialized bringup, the APIC ID is >> explicitly passed in the low bits of smpboot_control, while for parallel >> mode there are flags directing the AP to find its APIC ID in CPUID leaf >> 0x0b (for X2APIC mode) or CPUID leaf 0x01 where 8 bits are sufficient. > > For the serialized bringup case, it would be simpler to just put the > cpu number in the lower bits instead of the APIC id, skipping the > lookup. Yes and no. It can be done, but I rather prefer the consistency of the data and the mechanism. The "overhead" or "win" is not even measurable. Thanks, tglx