On 1/20/23 12:56, Thomas Huth wrote:
On 18/01/2023 18.09, Pierre Morel wrote:
On 1/12/23 12:52, Thomas Huth wrote:
On 05/01/2023 15.53, Pierre Morel wrote:
...>>> +#
OK
+# Emitted when the guest asks to change the polarity.
+#
+# @polarity: polarity specified by the guest
Please elaborate: Where does the value come from (the PTF
instruction)? Which values are possible?
Yes what about:
# @polarity: the guest can specify with the PTF instruction a horizontal
# or a vertical polarity.
Maybe something like: "The guest can tell the host (via the PTF
instruction) whether a CPU should have horizontal or vertical polarity." ?
Yes thanks, much better.
# On horizontal polarity the host is expected to provision
# the vCPU equally.
Maybe: "all vCPUs equally" ?
Or: "each vCPU equally" ?
yes, thx.
# On vertical polarity the host can provision each vCPU
# differently
# The guest can get information on the provisioning with
# the STSI(15) instruction.
Thomas
I make the changes.
Regards,
Pierre
--
Pierre Morel
IBM Lab Boeblingen