On Fri, Jan 07, 2022 at 10:31:59AM +0200, Maxim Levitsky wrote: >On Fri, 2022-01-07 at 16:05 +0800, Zeng Guang wrote: >> On 1/6/2022 10:06 PM, Tom Lendacky wrote: >> > On 1/5/22 7:44 PM, Zeng Guang wrote: >> > > On 1/6/2022 3:13 AM, Tom Lendacky wrote: >> > > > On 12/31/21 8:28 AM, Zeng Guang wrote: >> > > > Won't this blow up on AMD since there is no corresponding SVM op? >> > > > >> > > > Thanks, >> > > > Tom >> > > Right, need check ops validness to avoid ruining AMD system. Same >> > > consideration on ops "update_ipiv_pid_table" in patch8. >> > Not necessarily for patch8. That is "protected" by the >> > kvm_check_request(KVM_REQ_PID_TABLE_UPDATE, vcpu) test, but it couldn't hurt. >> >> OK, make sense. Thanks. > >I haven't fully reviewed this patch series yet, >and I will soon. > >I just want to point out few things: Thanks for pointing them out. > >1. AMD's AVIC also has a PID table (its calle AVIC physical ID table). >It stores addressses of vCPUs apic backing pages, >and thier real APIC IDs. > >avic_init_backing_page initializes the entry (assuming apic_id == vcpu_id) >(which is double confusing) > >2. For some reason KVM supports writable APIC IDs. Does anyone use these? >Even Intel's PRM strongly discourages users from using them and in X2APIC mode, >the APIC ID is read only. > >Because of this we have quite some bookkeeping in lapic.c, >(things like kvm_recalculate_apic_map and such) > >Also AVIC has its own handling for writes to APIC_ID,APIC_LDR,APIC_DFR >which tries to update its physical and logical ID tables. Intel's IPI virtualization doesn't handle logical-addressing IPIs. They cause APIC-write vm-exit as usual. So, this series doesn't handle APIC_LDR/DFR. > >(it used also to handle apic base and I removed this as apic base otherwise >was always hardcoded to the default vaule) > >Note that avic_handle_apic_id_update is broken - it always copies the entry >from the default (apicid == vcpu_id) location to new location and zeros >the old location, which will fail in many cases, like even if the guest >were to swap few apic ids. This series differs from avic_handle_apic_id_update slightly: If a vCPU's APIC ID is changed, this series zeros the old entry in PID-pointer table and programs the vCPU's PID to the new entry (rather than copy from the old entry). But this series is also problematic if guest swaps two vCPU's APIC ID without using another free APIC ID; it would end up one of them having no valid entry. One solution in my mind is: when a vCPU's APIC ID is changed, KVM traverses all vCPUs to count vCPUs using the old APIC ID and the new APIC ID, programs corrsponding entries following below rules: 1. populate an entry with a vCPU's PID if the corrsponding APIC ID is exclusively used by that vCPU. 2. zero an entry for other cases. Proper locking is needed in this process to prevent changes to vCPUs' APIC IDs. Or if it doesn't worth it, we can disable IPI virtualization for a guest on its first attempt to change xAPIC ID. Let us know which option is preferred.