The PEBS-PDIR facility on Ice Lake server is supported on IA31_FIXED0 only. If the guest configures counter 32 and PEBS is enabled, the PEBS-PDIR facility is supposed to be used, in which case KVM adjusts attr.precise_ip to 3 and request host perf to assign the exactly requested counter or fail. The cpu model check is also required since some platforms may place the PEBS-PDIR facility in another counter index. Signed-off-by: Like Xu <like.xu@xxxxxxxxxxxxxxx> --- arch/x86/kvm/pmu.c | 2 ++ arch/x86/kvm/pmu.h | 7 +++++++ 2 files changed, 9 insertions(+) diff --git a/arch/x86/kvm/pmu.c b/arch/x86/kvm/pmu.c index 0f86c1142f17..d3f746877d1b 100644 --- a/arch/x86/kvm/pmu.c +++ b/arch/x86/kvm/pmu.c @@ -149,6 +149,8 @@ static void pmc_reprogram_counter(struct kvm_pmc *pmc, u32 type, * in the PEBS record is calibrated on the guest side. */ attr.precise_ip = 1; + if (x86_match_cpu(vmx_icl_pebs_cpu) && pmc->idx == 32) + attr.precise_ip = 3; } event = perf_event_create_kernel_counter(&attr, -1, current, diff --git a/arch/x86/kvm/pmu.h b/arch/x86/kvm/pmu.h index 67e753edfa22..1af86ae1d3f2 100644 --- a/arch/x86/kvm/pmu.h +++ b/arch/x86/kvm/pmu.h @@ -4,6 +4,8 @@ #include <linux/nospec.h> +#include <asm/cpu_device_id.h> + #define vcpu_to_pmu(vcpu) (&(vcpu)->arch.pmu) #define pmu_to_vcpu(pmu) (container_of((pmu), struct kvm_vcpu, arch.pmu)) #define pmc_to_pmu(pmc) (&(pmc)->vcpu->arch.pmu) @@ -16,6 +18,11 @@ #define VMWARE_BACKDOOR_PMC_APPARENT_TIME 0x10002 #define MAX_FIXED_COUNTERS 3 +static const struct x86_cpu_id vmx_icl_pebs_cpu[] = { + X86_MATCH_INTEL_FAM6_MODEL(ICELAKE_D, NULL), + X86_MATCH_INTEL_FAM6_MODEL(ICELAKE_X, NULL), + {} +}; struct kvm_event_hw_type_mapping { u8 eventsel; -- 2.31.1