Re: [kvm-unit-tests PATCH v4] s390x: Load reset psw on diag308 reset

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On 13.11.19 12:24, Janosch Frank wrote:
On a diag308 subcode 0 CRs will be reset, so we need a PSW mask
without DAT. Also we need to set the short psw indication to be
compliant with the architecture.

Let's therefore define a reset PSW mask with 64 bit addressing and
short PSW indication that is compliant with architecture and use it.

Signed-off-by: Janosch Frank <frankja@xxxxxxxxxxxxx>
Reviewed-by: Thomas Huth <thuth@xxxxxxxxxx>

Queued to

https://github.com/davidhildenbrand/kvm-unit-tests.git s390x-next

I'll most probably wait a bit for the SCLP stuff to settle to send a pull request!

--

Thanks,

David / dhildenb