[PULL 03/10] arm: timer: Split variable output data from test name

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



From: Andre Przywara <andre.przywara@xxxxxxx>

For some tests we mix variable diagnostic output with the test name,
which leads to variable test line, confusing some higher level
frameworks.

Split the output to always use the same test name for a certain test,
and put diagnostic output on a separate line using the INFO: tag.

Signed-off-by: Andre Przywara <andre.przywara@xxxxxxx>
Reviewed-by: Andrew Jones <drjones@xxxxxxxxxx>
Signed-off-by: Andrew Jones <drjones@xxxxxxxxxx>
---
 arm/timer.c | 3 ++-
 1 file changed, 2 insertions(+), 1 deletion(-)

diff --git a/arm/timer.c b/arm/timer.c
index f2f60192ba62..0b808d5da9da 100644
--- a/arm/timer.c
+++ b/arm/timer.c
@@ -249,7 +249,8 @@ static void test_timer(struct timer_info *info)
 	local_irq_enable();
 	left = info->read_tval();
 	report("interrupt received after TVAL/WFI", info->irq_received);
-	report("timer has expired (%d)", left < 0, left);
+	report("timer has expired", left < 0);
+	report_info("TVAL is %d ticks", left);
 }
 
 static void test_vtimer(void)
-- 
2.21.0