On Mon, Jul 06, 2015 at 04:33:05PM +0200, Daniel Vetter wrote: > On Mon, Jul 06, 2015 at 02:16:54PM +0100, Dave Gordon wrote: > > On 06/07/15 13:38, Daniel Vetter wrote: > > >On Mon, Jul 06, 2015 at 12:52:51PM +0100, Dave Gordon wrote: > > >>On 03/07/15 16:42, Chris Wilson wrote: > > >>>On Fri, Jul 03, 2015 at 02:27:31PM +0100, Arun Siluvery wrote: > > >>>>In this WA we need to set GEN8_L3SQCREG4[21:21] and reset it after PIPE_CONTROL > > >>>>instruction but there is a slight complication as this is applied in WA batch > > >>>>where the values are only initialized once. > > >>>>Dave identified an issue with the current implementation where the register value > > >>>>is read once at the beginning and it is reused; this patch corrects this by saving > > >>>>the register value to memory, update register with the bit of our interest and > > >>>>restore it back with original value. > > >>>> > > >>>>This implementation uses MI_LOAD_REGISTER_MEM which is currently only used > > >>>>by command parser and was using a default length of 0. This is now updated > > >>>>with correct length and moved to appropriate place. > > >>>> > > >>>>Cc: Chris Wilson <chris@xxxxxxxxxxxxxxxxxx> > > >>>>Cc: Dave Gordon <david.s.gordon@xxxxxxxxx> > > >>>>Signed-off-by: Arun Siluvery <arun.siluvery@xxxxxxxxxxxxxxx> > > >>>>--- > > >>>> drivers/gpu/drm/i915/i915_cmd_parser.c | 6 +-- > > >>>> drivers/gpu/drm/i915/i915_reg.h | 3 +- > > >>>> drivers/gpu/drm/i915/intel_lrc.c | 72 +++++++++++++++++++++++++--------- > > >>>> 3 files changed, 58 insertions(+), 23 deletions(-) > > >>>> > > >>>>diff --git a/drivers/gpu/drm/i915/i915_cmd_parser.c b/drivers/gpu/drm/i915/i915_cmd_parser.c > > >>>>index 306d9e4..430571b 100644 > > >>>>--- a/drivers/gpu/drm/i915/i915_cmd_parser.c > > >>>>+++ b/drivers/gpu/drm/i915/i915_cmd_parser.c > > > > >>>>@@ -1021,7 +1021,7 @@ static bool check_cmd(const struct intel_engine_cs *ring, > > >>>> * only MI_LOAD_REGISTER_IMM commands. > > >>>> */ > > >>>> if (reg_addr == OACONTROL) { > > >>>>- if (desc->cmd.value == MI_LOAD_REGISTER_MEM) { > > >>>>+ if (desc->cmd.value == MI_LOAD_REGISTER_MEM(1)) { > > >>> > > >>>I had a double take here, but it all comes out in the wash. For one > > >>>moment, I thought the cmd matching had changed, but that has the length > > >>>masked out. > > >>> > > >>>Reviewed-by: Chris Wilson <chris@xxxxxxxxxxxxxxxxx> > > > > > >Queued for -next, thanks for the patch. > > > > > >>>Who will start to complain about all the extra frequent register writes, > > >>>probably into common power wells.... > > >>>-Chris > > >> > > >>Hmm ... that is quite confusing, especially as the actual opcode in the > > >>instruction stream will be MI_LOAD_REGISTER_MEM(2) on GEN8+. It might almost > > >>be better to use MI_LOAD_REGISTER_MEM(0) to emphasise that the length field > > >>is a wildcard and not something that will be matched exactly. > > > > > >There's a separate _GEN8 #define to accomodate the differences, so I don't > > >fully understand your concern. We also don't do any decoding in the kernel > > >... > > >-Daniel > > > > In the snippet: > > > > >> - CMD( MI_LOAD_REGISTER_MEM, SMI, !F, 0xFF, W | B, > > >> + CMD( MI_LOAD_REGISTER_MEM(1), SMI, !F, 0xFF, W | B, > > > > the (1) goes in the table but is ignored when matching instructions in the > > stream being parsed. It could just as well be (2) or (0) or (255). > > > > Then, in the test: > > > > >> - if (desc->cmd.value == MI_LOAD_REGISTER_MEM) { > > >> + if (desc->cmd.value == MI_LOAD_REGISTER_MEM(1)) { > > > > the thing on the left of the == is not the instruction being examined, but > > the entry in the table that matched that instruction. So here also we're not > > really using the length field, EXCEPT that it MUST be the same as the > > (arbitrary) value in the table. > > > > So my concern here was not about correctness but comprehensibility and hence > > maintainability -- after all, if Chris had to look twice it obviously isn't > > as clear as one would like! > > > > My suggestion was that maybe the "ignored" length field should be 0 to make > > it less likely that a reader would think this matches exactly (and only) an > > opcode of 0xa400001. Or maybe (255) would be even more obviously > > not-a-literal-match? > > Hm, given that the cmd parser is gen7 only I'm not too concerned about > this. It is indeed a bit surprising though, and I guess (0) would be less > surprising. Otoh other commands with a lenght field also use (1) in a > similar fashion, so at least this is consistent. > > tbh no opinion here at all from my side, but happy to merge a fixup on top > to clarify this, if you can agree on a clear improvement. iirc, the #define used CMD | (2*(x)-1), which blows up if passed in 0. -Chris -- Chris Wilson, Intel Open Source Technology Centre _______________________________________________ Intel-gfx mailing list Intel-gfx@xxxxxxxxxxxxxxxxxxxxx http://lists.freedesktop.org/mailman/listinfo/intel-gfx