On Thu, Feb 26, 2015 at 06:19:41PM +0530, akash.goel@xxxxxxxxx wrote: > From: Akash Goel <akash.goel@xxxxxxxxx> > > Prior to SKL, the time period programmed in Up/Down EI & Up/Down > threshold registers was in units of 1.28 micro seconds. But for > SKL, the units have changed (1.333 micro seconds). > Have generalized the implementation of gen6_set_rps_thresholds function, > by removing the hard coding done in it as per 1.28 micro seconds. > > v2: Renamed the local variables & removed superfluous comments (Chris) > > Signed-off-by: Akash Goel <akash.goel@xxxxxxxxx> Reviewed-by: Chris Wilson <chris@xxxxxxxxxxxxxxxxxx> -Chris -- Chris Wilson, Intel Open Source Technology Centre _______________________________________________ Intel-gfx mailing list Intel-gfx@xxxxxxxxxxxxxxxxxxxxx http://lists.freedesktop.org/mailman/listinfo/intel-gfx