Hi All, I submitted a patch and it show to fail in CI. Does the message means it is failed because of "ro-bdw-i7-5557U failed to connect after reboot". And how can I get the dmesg? Regards, Libin > -----Original Message----- > From: Intel-gfx [mailto:intel-gfx-bounces@xxxxxxxxxxxxxxxxxxxxx] On Behalf Of > Patchwork > Sent: Thursday, July 14, 2016 3:39 PM > To: libin.yang@xxxxxxxxxxxxxxx > Cc: intel-gfx@xxxxxxxxxxxxxxxxxxxxx > Subject: ✗ Ro.CI.BAT: failure for drm/i915: set proper N/M in > modeset > > == Series Details == > > Series: drm/i915: set proper N/M in modeset > URL : https://patchwork.freedesktop.org/series/9857/ > State : failure > > == Summary == > > Series 9857v1 drm/i915: set proper N/M in modeset > http://patchwork.freedesktop.org/api/1.0/series/9857/revisions/1/mbox > > Test drv_module_reload_basic: > dmesg-warn -> SKIP (fi-skl-i5-6260u) > Test kms_pipe_crc_basic: > Subgroup suspend-read-crc-pipe-b: > pass -> DMESG-WARN (ro-skl3-i5-6260u) > Test prime_self_import: > Subgroup basic-with_fd_dup: > pass -> INCOMPLETE (ro-byt-n2820) > Subgroup basic-with_one_bo_two_files: > pass -> INCOMPLETE (ro-byt-n2820) > Subgroup basic-with_two_bos: > pass -> INCOMPLETE (ro-byt-n2820) > > fi-kbl-qkkr total:237 pass:174 dwarn:27 dfail:2 fail:7 skip:27 > fi-skl-i5-6260u total:237 pass:189 dwarn:26 dfail:2 fail:7 skip:13 > fi-skl-i7-6700k total:237 pass:200 dwarn:2 dfail:0 fail:9 skip:26 > fi-snb-i7-2600 total:237 pass:188 dwarn:0 dfail:0 fail:9 skip:40 > ro-bdw-i5-5250u total:237 pass:210 dwarn:2 dfail:0 fail:9 skip:16 > ro-bdw-i7-5600u total:237 pass:195 dwarn:2 dfail:0 fail:9 skip:31 > ro-bsw-n3050 total:217 pass:170 dwarn:0 dfail:0 fail:4 skip:42 > ro-byt-n2820 total:237 pass:174 dwarn:0 dfail:0 fail:7 skip:38 > ro-hsw-i3-4010u total:237 pass:199 dwarn:5 dfail:2 fail:7 skip:24 > ro-hsw-i7-4770r total:237 pass:204 dwarn:0 dfail:0 fail:9 skip:24 > ro-ilk-i7-620lm total:237 pass:166 dwarn:0 dfail:0 fail:8 skip:63 > ro-ilk1-i5-650 total:232 pass:166 dwarn:0 dfail:0 fail:8 skip:58 > ro-ivb-i7-3770 total:237 pass:197 dwarn:0 dfail:0 fail:7 skip:33 > ro-skl3-i5-6260u total:237 pass:212 dwarn:4 dfail:0 fail:9 skip:12 > ro-snb-i7-2620M total:237 pass:187 dwarn:0 dfail:0 fail:9 skip:41 > ro-bdw-i7-5557U failed to connect after reboot > > Results at /archive/results/CI_IGT_test/RO_Patchwork_1490/ > > 5cd2699 drm-intel-nightly: 2016y-07m-13d-14h-43m-27s UTC integration > manifest 9ea6eab drm/i915: set proper N/M in modeset > > _______________________________________________ > Intel-gfx mailing list > Intel-gfx@xxxxxxxxxxxxxxxxxxxxx > https://lists.freedesktop.org/mailman/listinfo/intel-gfx _______________________________________________ Intel-gfx mailing list Intel-gfx@xxxxxxxxxxxxxxxxxxxxx https://lists.freedesktop.org/mailman/listinfo/intel-gfx