On 2/12/2021 4:01 AM, tom petch wrote: > On 11/02/2021 09:39, Dhruv Dhody wrote: >> ... > > leaf poll { > type uint8; > This seems wrong to me. Looking at s.7.3 > Poll: 8-bit signed integer representing the maximum interval between > successive messages, in log2 seconds. Suggested default limits for > minimum and maximum poll intervals are 6 and 10, respectively. > ie signed integer and not uint Why are 6 and 10 useful as suggested limits for minimum and maximum poll values? -- Harlan Stenn <stenn@xxxxxxxxxx> http://networktimefoundation.org - be a member! -- last-call mailing list last-call@xxxxxxxx https://www.ietf.org/mailman/listinfo/last-call