The channel configuration in CHAN_SWITCH command was incorrect. This resulted in switching to HT40+ channel, while announcing HT40- in the secondary channel IE. This caused a disconnection after the channel switch. Fix that. Signed-off-by: Andrei Otcheretianski <andrei.otcheretianski@xxxxxxxxx> --- tests/hwsim/test_ap_vht.py | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/tests/hwsim/test_ap_vht.py b/tests/hwsim/test_ap_vht.py index c9f299f..107fa50 100644 --- a/tests/hwsim/test_ap_vht.py +++ b/tests/hwsim/test_ap_vht.py @@ -732,7 +732,7 @@ def test_ap_vht_csa_vht40(dev, apdev): dev[0].connect("vht", key_mgmt="NONE", scan_freq="5745") hwsim_utils.test_connectivity(dev[0], hapd) - hapd.request("CHAN_SWITCH 5 5765 sec_channel_offset=-1 center_freq1=5775 bandwidth=40 vht") + hapd.request("CHAN_SWITCH 5 5765 sec_channel_offset=-1 center_freq1=5755 bandwidth=40 vht") ev = hapd.wait_event(["AP-CSA-FINISHED"], timeout=10) if ev is None: raise Exception("CSA finished event timed out") -- 2.7.4 _______________________________________________ Hostap mailing list Hostap@xxxxxxxxxxxxxxxxxxx http://lists.infradead.org/mailman/listinfo/hostap