On Thu, Aug 02, 2018 at 01:22:59PM -0700, Joshua Zhao wrote: > Hi, > I'm running the open source 11s mesh with QCA Dakota radios. But as we > set up more spaces, say > 4 spaces, mesh authentication starts to > become difficult. As I look into the code, it appears to me that the > SAE state machine is not tracking/identifying the peers? So when the > commit & confirm messages between multiple peers interleave each > other, the state machine either sees ECC/FFC mismatch or keeps > resetting the states. > > Is my observation correct? And is this a known issue? The peers are tracked: this is what the sta parameter in sae_sm_step() is for. What hardware is this? Some devices have limits in terms of the number of peers or keys they can handle. -- Bob Copeland %% https://bobcopeland.com/ _______________________________________________ Hostap mailing list Hostap@xxxxxxxxxxxxxxxxxxx http://lists.infradead.org/mailman/listinfo/hostap