I tried to debug the inode* related leaks and seen some improvements
after applying the below patches when ran the same test (but will
smaller load). Could you please apply those patches & confirm the same?
a) http://review.gluster.org/13125
This will fix the inodes & their ctx related leaks during unexport and
the program exit. Please check the valgrind output after applying the
patch. It should not list any inodes related memory as lost.
b) http://review.gluster.org/13096
The reason the change in Entries_HWMARK (in your earlier mail) dint have
much effect is that the inode_nlookup count doesn't become zero for
those handles/inodes being closed by ganesha. Hence those inodes shall
get added to inode lru list instead of purge list which shall get
forcefully purged only when the number of gfapi inode table entries
reaches its limit (which is 137012).
This patch fixes those 'nlookup' counts. Please apply this patch and
reduce 'Entries_HWMARK' to much lower value and check if it decreases
the in-memory being consumed by ganesha process while being active.
CACHEINODE {
Entries_HWMark = 500;
}
Note: I see an issue with nfs-ganesha during exit when the option
'Entries_HWMARK' gets changed. This is not related to any of the above
patches (or rather Gluster) and I am currently debugging it.
Thanks,
Soumya
On 12/25/2015 11:34 PM, Oleksandr Natalenko wrote:
1. test with Cache_Size = 256 and Entries_HWMark = 4096
Before find . -type f:
root 3120 0.6 11.0 879120 208408 ? Ssl 17:39 0:00 /usr/bin/
ganesha.nfsd -L /var/log/ganesha.log -f /etc/ganesha/ganesha.conf -N NIV_EVENT
After:
root 3120 11.4 24.3 1170076 458168 ? Ssl 17:39 13:39 /usr/bin/
ganesha.nfsd -L /var/log/ganesha.log -f /etc/ganesha/ganesha.conf -N NIV_EVENT
~250M leak.
2. test with default values (after ganesha restart)
Before:
root 24937 1.3 10.4 875016 197808 ? Ssl 19:39 0:00 /usr/bin/
ganesha.nfsd -L /var/log/ganesha.log -f /etc/ganesha/ganesha.conf -N NIV_EVENT
After:
root 24937 3.5 18.9 1022544 356340 ? Ssl 19:39 0:40 /usr/bin/
ganesha.nfsd -L /var/log/ganesha.log -f /etc/ganesha/ganesha.conf -N NIV_EVENT
~159M leak.
No reasonable correlation detected. Second test was finished much faster than
first (I guess, server-side GlusterFS cache or server kernel page cache is the
cause).
There are ~1.8M files on this test volume.
On пʼятниця, 25 грудня 2015 р. 20:28:13 EET Soumya Koduri wrote:
On 12/24/2015 09:17 PM, Oleksandr Natalenko wrote:
Another addition: it seems to be GlusterFS API library memory leak
because NFS-Ganesha also consumes huge amount of memory while doing
ordinary "find . -type f" via NFSv4.2 on remote client. Here is memory
usage:
===
root 5416 34.2 78.5 2047176 1480552 ? Ssl 12:02 117:54
/usr/bin/ganesha.nfsd -L /var/log/ganesha.log -f
/etc/ganesha/ganesha.conf -N NIV_EVENT
===
1.4G is too much for simple stat() :(.
Ideas?
nfs-ganesha also has cache layer which can scale to millions of entries
depending on the number of files/directories being looked upon. However
there are parameters to tune it. So either try stat with few entries or
add below block in nfs-ganesha.conf file, set low limits and check the
difference. That may help us narrow down how much memory actually
consumed by core nfs-ganesha and gfAPI.
CACHEINODE {
Cache_Size(uint32, range 1 to UINT32_MAX, default 32633); # cache size
Entries_HWMark(uint32, range 1 to UINT32_MAX, default 100000); #Max no.
of entries in the cache.
}
Thanks,
Soumya
24.12.2015 16:32, Oleksandr Natalenko написав:
Still actual issue for 3.7.6. Any suggestions?
24.09.2015 10:14, Oleksandr Natalenko написав:
In our GlusterFS deployment we've encountered something like memory
leak in GlusterFS FUSE client.
We use replicated (×2) GlusterFS volume to store mail (exim+dovecot,
maildir format). Here is inode stats for both bricks and mountpoint:
===
Brick 1 (Server 1):
Filesystem Inodes IUsed
IFree IUse% Mounted on
/dev/mapper/vg_vd1_misc-lv08_mail 578768144 10954918
567813226 2% /bricks/r6sdLV08_vd1_mail
Brick 2 (Server 2):
Filesystem Inodes IUsed
IFree IUse% Mounted on
/dev/mapper/vg_vd0_misc-lv07_mail 578767984 10954913
567813071 2% /bricks/r6sdLV07_vd0_mail
Mountpoint (Server 3):
Filesystem Inodes IUsed IFree
IUse% Mounted on
glusterfs.xxx:mail 578767760 10954915 567812845
2% /var/spool/mail/virtual
===
glusterfs.xxx domain has two A records for both Server 1 and Server 2.
Here is volume info:
===
Volume Name: mail
Type: Replicate
Volume ID: f564e85c-7aa6-4170-9417-1f501aa98cd2
Status: Started
Number of Bricks: 1 x 2 = 2
Transport-type: tcp
Bricks:
Brick1: server1.xxx:/bricks/r6sdLV08_vd1_mail/mail
Brick2: server2.xxx:/bricks/r6sdLV07_vd0_mail/mail
Options Reconfigured:
nfs.rpc-auth-allow: 1.2.4.0/24,4.5.6.0/24
features.cache-invalidation-timeout: 10
performance.stat-prefetch: off
performance.quick-read: on
performance.read-ahead: off
performance.flush-behind: on
performance.write-behind: on
performance.io-thread-count: 4
performance.cache-max-file-size: 1048576
performance.cache-size: 67108864
performance.readdir-ahead: off
===
Soon enough after mounting and exim/dovecot start, glusterfs client
process begins to consume huge amount of RAM:
===
user@server3 ~$ ps aux | grep glusterfs | grep mail
root 28895 14.4 15.0 15510324 14908868 ? Ssl Sep03 4310:05
/usr/sbin/glusterfs --fopen-keep-cache --direct-io-mode=disable
--volfile-server=glusterfs.xxx --volfile-id=mail
/var/spool/mail/virtual
===
That is, ~15 GiB of RAM.
Also we've tried to use mountpoint withing separate KVM VM with 2 or 3
GiB of RAM, and soon after starting mail daemons got OOM killer for
glusterfs client process.
Mounting same share via NFS works just fine. Also, we have much less
iowait and loadavg on client side with NFS.
Also, we've tried to change IO threads count and cache size in order
to limit memory usage with no luck. As you can see, total cache size
is 4×64==256 MiB (compare to 15 GiB).
Enabling-disabling stat-prefetch, read-ahead and readdir-ahead didn't
help as well.
Here are volume memory stats:
===
Memory status for volume : mail
----------------------------------------------
Brick : server1.xxx:/bricks/r6sdLV08_vd1_mail/mail
Mallinfo
--------
Arena : 36859904
Ordblks : 10357
Smblks : 519
Hblks : 21
Hblkhd : 30515200
Usmblks : 0
Fsmblks : 53440
Uordblks : 18604144
Fordblks : 18255760
Keepcost : 114112
Mempool Stats
-------------
Name HotCount ColdCount PaddedSizeof
AllocCount MaxAlloc Misses Max-StdAlloc
---- -------- --------- ------------
---------- -------- -------- ------------
mail-server:fd_t 0 1024 108
30773120 137 0 0
mail-server:dentry_t 16110 274 84
235676148 16384 1106499 1152
mail-server:inode_t 16363 21 156
237216876 16384 1876651 1169
mail-trash:fd_t 0 1024 108
0 0 0 0
mail-trash:dentry_t 0 32768 84
0 0 0 0
mail-trash:inode_t 4 32764 156
4 4 0 0
mail-trash:trash_local_t 0 64 8628
0 0 0 0
mail-changetimerecorder:gf_ctr_local_t 0 64
16540 0 0 0 0
mail-changelog:rpcsvc_request_t 0 8 2828
0 0 0 0
mail-changelog:changelog_local_t 0 64 116
0 0 0 0
mail-bitrot-stub:br_stub_local_t 0 512 84
79204 4 0 0
mail-locks:pl_local_t 0 32 148
6812757 4 0 0
mail-upcall:upcall_local_t 0 512 108
0 0 0 0
mail-marker:marker_local_t 0 128 332
64980 3 0 0
mail-quota:quota_local_t 0 64 476
0 0 0 0
mail-server:rpcsvc_request_t 0 512 2828
45462533 34 0 0
glusterfs:struct saved_frame 0 8 124
2 2 0 0
glusterfs:struct rpc_req 0 8 588
2 2 0 0
glusterfs:rpcsvc_request_t 1 7 2828
2 1 0 0
glusterfs:log_buf_t 5 251 140
3452 6 0 0
glusterfs:data_t 242 16141 52
480115498 664 0 0
glusterfs:data_pair_t 230 16153 68
179483528 275 0 0
glusterfs:dict_t 23 4073 140
303751675 627 0 0
glusterfs:call_stub_t 0 1024 3764
45290655 34 0 0
glusterfs:call_stack_t 1 1023 1708
43598469 34 0 0
glusterfs:call_frame_t 1 4095 172
336219655 184 0 0
----------------------------------------------
Brick : server2.xxx:/bricks/r6sdLV07_vd0_mail/mail
Mallinfo
--------
Arena : 38174720
Ordblks : 9041
Smblks : 507
Hblks : 21
Hblkhd : 30515200
Usmblks : 0
Fsmblks : 51712
Uordblks : 19415008
Fordblks : 18759712
Keepcost : 114848
Mempool Stats
-------------
Name HotCount ColdCount PaddedSizeof
AllocCount MaxAlloc Misses Max-StdAlloc
---- -------- --------- ------------
---------- -------- -------- ------------
mail-server:fd_t 0 1024 108
2373075 133 0 0
mail-server:dentry_t 14114 2270 84
3513654 16384 2300 267
mail-server:inode_t 16374 10 156
6766642 16384 194635 1279
mail-trash:fd_t 0 1024 108
0 0 0 0
mail-trash:dentry_t 0 32768 84
0 0 0 0
mail-trash:inode_t 4 32764 156
4 4 0 0
mail-trash:trash_local_t 0 64 8628
0 0 0 0
mail-changetimerecorder:gf_ctr_local_t 0 64
16540 0 0 0 0
mail-changelog:rpcsvc_request_t 0 8 2828
0 0 0 0
mail-changelog:changelog_local_t 0 64 116
0 0 0 0
mail-bitrot-stub:br_stub_local_t 0 512 84
71354 4 0 0
mail-locks:pl_local_t 0 32 148
8135032 4 0 0
mail-upcall:upcall_local_t 0 512 108
0 0 0 0
mail-marker:marker_local_t 0 128 332
65005 3 0 0
mail-quota:quota_local_t 0 64 476
0 0 0 0
mail-server:rpcsvc_request_t 0 512 2828
12882393 30 0 0
glusterfs:struct saved_frame 0 8 124
2 2 0 0
glusterfs:struct rpc_req 0 8 588
2 2 0 0
glusterfs:rpcsvc_request_t 1 7 2828
2 1 0 0
glusterfs:log_buf_t 5 251 140
3443 6 0 0
glusterfs:data_t 242 16141 52
138743429 290 0 0
glusterfs:data_pair_t 230 16153 68
126649864 270 0 0
glusterfs:dict_t 23 4073 140
20356289 63 0 0
glusterfs:call_stub_t 0 1024 3764
13678560 31 0 0
glusterfs:call_stack_t 1 1023 1708
11011561 30 0 0
glusterfs:call_frame_t 1 4095 172
125764190 193 0 0
----------------------------------------------
===
So, my questions are:
1) what one should do to limit GlusterFS FUSE client memory usage?
2) what one should do to prevent client high loadavg because of high
iowait because of multiple concurrent volume users?
Server/client OS is CentOS 7.1, GlusterFS server version is 3.7.3,
GlusterFS client version is 3.7.4.
Any additional info needed?