Emmanuel, I tried re-creating the issue on master. It gives ENOTCONN as expected. Could you let me know on which version you get EAGAIN?. [root@pranithk-laptop r2]# touch a ----- Brought both the bricks down.------- [root@pranithk-laptop r2]# unlink a unlink: cannot unlink `a': Transport endpoint is not connected Pranith. ----- Original Message ----- From: Emmanuel Dreyfus <manu@xxxxxxxxxx> To: Anand Avati <anand.avati@xxxxxxxxx> Cc: gluster-devel@xxxxxxxxxx Sent: Tue, 24 Jul 2012 01:05:32 -0400 (EDT) Subject: Re: all server down Anand Avati <anand.avati@xxxxxxxxx> wrote: > For which operation are you finding EAGAIN when all servers are down? It is > probably a wrong errno coming along. You shouldn't need to do anything in > the FUSE layer, just send it back to the application. It was on an unlink. -- Emmanuel Dreyfus http://hcpnet.free.fr/pubz manu@xxxxxxxxxx _______________________________________________ Gluster-devel mailing list Gluster-devel@xxxxxxxxxx https://lists.nongnu.org/mailman/listinfo/gluster-devel