Hello,
I'm running glusterfs--mainline--2.5--patch-770 (glusterfs 1.3.9) and
fuse-2.7.3glfs10 on 3 test machines with AFR with client side
replication. My test setup is: 2 glusterfs servers and 3 glusterfs
clients .The one machine is configured as client only and two are
configured as server and client. While running tests with bonnie++ on
the three clients (3 bonnies in parallel) I kill the one glusterfs
server process and start again. After two or three test cycles one of
the bonnies didn't finish at all with one of the errors:
"Can't open file ./Bonnie.17791.001"
"Can't open file 0000267hWNIpRcI"
"Expected 1024 files but only got 1039"
The glusterfs client log messages are:
2008-05-27 15:44:28 E [afr.c:1239:afr_selfheal_setxattr_cbk] afr:
(path=/Bonnie.1918/00002/0000267hWNIpRcI child=client-wks12) op_ret=-1
op_errno=107
2008-05-27 15:44:28 W [client-protocol.c:332:client_protocol_xfer]
client-wks1: not connected at the moment to submit frame type(1) op(31)
2008-05-27 15:44:28 E [client-protocol.c:2731:client_utimens_cbk]
client-wks1: no proper reply from server, returning ENOTCONN
2008-05-27 15:44:28 E [afr.c:1279:afr_selfheal_utimens_cbk] afr:
(path=/Bonnie.1918/00002/0000267hWNIpRcI child=client-wks1) op_ret=-1
op_errno=107
2008-05-27 15:44:28 W [client-protocol.c:332:client_protocol_xfer]
client-wks1: not connected at the moment to submit frame type(2) op(6)
2008-05-27 15:44:28 E [client-protocol.c:4270:client_unlock_cbk]
client-wks1: no proper reply from server, returning ENOTCONN
2008-05-27 15:44:28 E [afr.c:1140:afr_selfheal_unlock_cbk] afr:
(path=/Bonnie.1918/00002/0000267hWNIpRcI child=client-wks1) op_ret=-1
op_errno=107
2008-05-27 15:44:28 E [afr.c:2177:afr_open] afr: self heal failed,
returning EIO
2008-05-27 15:44:28 E [fuse-bridge.c:692:fuse_fd_cbk] glusterfs-fuse:
113365: (12) /Bonnie.1918/00002/0000267hWNIpRcI => -1 (5)
My config files on the two client and server mashines are:
cat /etc/glusterfs/glusterfs-server.vol
volume brick-local
type storage/posix
option directory /test
end-volume
volume p-locks
type features/posix-locks
subvolumes brick-local
option mandatory on
end-volume
volume server
type protocol/server
option transport-type tcp/server
subvolumes p-locks
option auth.ip.p-locks.allow *
end-volume
cat /etc/glusterfs/glusterfs-client.vol
volume client-wks2
type protocol/client
option transport-type tcp/client
option remote-host 10.0.0.2
option remote-subvolume p-locks
option transport-timeout 5
end-volume
volume client-wks1
type protocol/client
option transport-type tcp/client
option remote-host 10.0.0.1
option remote-subvolume p-locks
option transport-timeout 5
end-volume
volume afr
type cluster/afr
subvolumes client-wks2 client-wks1
end-volume
And this is config file on the third only glusterfs client mashine:
/etc/glusterfs/glusterfs-client.vol
volume client-wks1
type protocol/client
option transport-type tcp/client
option remote-host 10.0.0.1
option remote-subvolume p-locks
option transport-timeout 5
end-volume
volume client-wks2
type protocol/client
option transport-type tcp/client
option remote-host 10.0.0.2
option remote-subvolume p-lock
option transport-timeout 5
end-volume
volume afr
type cluster/afr
subvolumes client-wks1 client-wks2
end-volume
Can you tell me what is wrong? Please advise and thanks in advance!
Thanks,
Snezhana
-------------------------------------