Migrate away from custom EDID parsing and validity checks. Signed-off-by: Jani Nikula <jani.nikula@xxxxxxxxx> Signed-off-by: Ian Ray <ian.ray@xxxxxx> --- .../drm/bridge/megachips-stdpxxxx-ge-b850v3-fw.c | 57 ++++------------------ 1 file changed, 9 insertions(+), 48 deletions(-) diff --git a/drivers/gpu/drm/bridge/megachips-stdpxxxx-ge-b850v3-fw.c b/drivers/gpu/drm/bridge/megachips-stdpxxxx-ge-b850v3-fw.c index 460db3c..e93083b 100644 --- a/drivers/gpu/drm/bridge/megachips-stdpxxxx-ge-b850v3-fw.c +++ b/drivers/gpu/drm/bridge/megachips-stdpxxxx-ge-b850v3-fw.c @@ -65,12 +65,11 @@ struct ge_b850v3_lvds { static struct ge_b850v3_lvds *ge_b850v3_lvds_ptr; -static u8 *stdp2690_get_edid(struct i2c_client *client) +static int stdp2690_read_block(void *context, u8 *buf, unsigned int block, size_t len) { + struct i2c_client *client = context; struct i2c_adapter *adapter = client->adapter; - unsigned char start = 0x00; - unsigned int total_size; - u8 *block = kmalloc(EDID_LENGTH, GFP_KERNEL); + unsigned char start = block * EDID_LENGTH; struct i2c_msg msgs[] = { { @@ -81,53 +80,15 @@ static u8 *stdp2690_get_edid(struct i2c_client *client) }, { .addr = client->addr, .flags = I2C_M_RD, - .len = EDID_LENGTH, - .buf = block, + .len = len, + .buf = buf, } }; - if (!block) - return NULL; + if (i2c_transfer(adapter, msgs, 2) != 2) + return -1; - if (i2c_transfer(adapter, msgs, 2) != 2) { - DRM_ERROR("Unable to read EDID.\n"); - goto err; - } - - if (!drm_edid_block_valid(block, 0, false, NULL)) { - DRM_ERROR("Invalid EDID data\n"); - goto err; - } - - total_size = (block[EDID_EXT_BLOCK_CNT] + 1) * EDID_LENGTH; - if (total_size > EDID_LENGTH) { - kfree(block); - block = kmalloc(total_size, GFP_KERNEL); - if (!block) - return NULL; - - /* Yes, read the entire buffer, and do not skip the first - * EDID_LENGTH bytes. - */ - start = 0x00; - msgs[1].len = total_size; - msgs[1].buf = block; - - if (i2c_transfer(adapter, msgs, 2) != 2) { - DRM_ERROR("Unable to read EDID extension blocks.\n"); - goto err; - } - if (!drm_edid_block_valid(block, 1, false, NULL)) { - DRM_ERROR("Invalid EDID data\n"); - goto err; - } - } - - return block; - -err: - kfree(block); - return NULL; + return 0; } static struct edid *ge_b850v3_lvds_get_edid(struct drm_bridge *bridge, @@ -137,7 +98,7 @@ static struct edid *ge_b850v3_lvds_get_edid(struct drm_bridge *bridge, client = ge_b850v3_lvds_ptr->stdp2690_i2c; - return (struct edid *)stdp2690_get_edid(client); + return drm_do_get_edid(connector, stdp2690_read_block, client); } static int ge_b850v3_lvds_get_modes(struct drm_connector *connector) -- 2.10.1