Some Displays support more than just a single default lvds data mapping, which can be used to run displays on only 3 LVDS lanes in the jeida-18 data-mapping mode. Add an optional data-mapping property to allow overriding the default data mapping. As it does not generally apply to any display and bus: use it selectively on the innolux,g101ice-l01, which supports changing the data mapping via a strapping pin. Signed-off-by: Johannes Zink <j.zink@xxxxxxxxxxxxxx> --- Changes: v1 -> v2: - worked in Rob's review findings (thanks for reviewing my work): use extracted common property instead of duplicating the property - refined commit message - add an example dts for automated checking --- .../bindings/display/panel/panel-simple.yaml | 26 +++++++++++++++++++++- 1 file changed, 25 insertions(+), 1 deletion(-) diff --git a/Documentation/devicetree/bindings/display/panel/panel-simple.yaml b/Documentation/devicetree/bindings/display/panel/panel-simple.yaml index ec50dd268314..698301c8c920 100644 --- a/Documentation/devicetree/bindings/display/panel/panel-simple.yaml +++ b/Documentation/devicetree/bindings/display/panel/panel-simple.yaml @@ -21,9 +21,9 @@ description: | allOf: - $ref: panel-common.yaml# + - $ref: ../lvds-data-mapping.yaml# properties: - compatible: enum: # compatible must be listed in alphabetical order, ordered by compatible. @@ -353,6 +353,17 @@ properties: power-supply: true no-hpd: true hpd-gpios: true + data-mapping: true + +if: + not: + properties: + compatible: + contains: + const: innolux,g101ice-l01 +then: + properties: + data-mapping: false additionalProperties: false @@ -372,3 +383,16 @@ examples: }; }; }; + - | + panel_lvds: panel-lvds { + compatible = "innolux,g101ice-l01"; + power-supply = <&vcc_lcd_reg>; + + data-mapping = "jeida-24"; + + port { + panel_in_lvds: endpoint { + remote-endpoint = <<dc_out_lvds>; + }; + }; + }; -- 2.39.2