Bug ID | 107143 |
---|---|
Summary | Prime - OverDrive volt and frequency table(pp_od_clk_voltage) is reset every time on power on |
Product | DRI |
Version | unspecified |
Hardware | x86-64 (AMD64) |
OS | Linux (All) |
Status | NEW |
Severity | normal |
Priority | medium |
Component | DRM/AMDgpu |
Assignee | dri-devel@lists.freedesktop.org |
Reporter | rune@megahurts.dk |
OverDrive volt and frequency table(pp_od_clk_voltage) is reset every time on power on. For most desktop this is not a problem since, the GPU is not powered off until you turn off the computer. When you use PRIME, the dGPU is powered off every time you stop using it, which again means that next time it is powered all OverDrive table changes will be lost. Distro: Debian Kernel: 4.17.3(custom) Machine: HP ZBook 15 G4 Mobile Workstation. CPU: i7-7700HQ dGPU: AMD Radeon Pro WX 4150
You are receiving this mail because:
- You are the assignee for the bug.
_______________________________________________ dri-devel mailing list dri-devel@xxxxxxxxxxxxxxxxxxxxx https://lists.freedesktop.org/mailman/listinfo/dri-devel