Update the bindings with the new properties used for PMI8998. Signed-off-by: Kiran Gunda <kgunda@xxxxxxxxxxxxxx> --- .../bindings/leds/backlight/qcom-wled.txt | 84 ++++++++++++++++++++-- 1 file changed, 77 insertions(+), 7 deletions(-) diff --git a/Documentation/devicetree/bindings/leds/backlight/qcom-wled.txt b/Documentation/devicetree/bindings/leds/backlight/qcom-wled.txt index 14f28f2..503ce87 100644 --- a/Documentation/devicetree/bindings/leds/backlight/qcom-wled.txt +++ b/Documentation/devicetree/bindings/leds/backlight/qcom-wled.txt @@ -48,11 +48,15 @@ platforms. The PMIC is connected to the host processor via SPMI bus. - qcom,current-limit Usage: optional Value type: <u32> - Definition: mA; per-string current limit - value: For pm8941: from 0 to 25 with 5 mA step - Default 20 mA. - For pmi8998: from 0 to 30 with 5 mA step - Default 25 mA. + Definition: mA; per-string current limit; value from 0 to 25 with + 1 mA step. Default 20 mA. + This property is supported only for pm8941. + +- qcom,current-limit-microamp + Usage: optional + Value type: <u32> + Definition: uA; per-string current limit; value from 0 to 30000 with + 2500 uA step. Default 25000 uA. - qcom,current-boost-limit Usage: optional @@ -79,12 +83,61 @@ platforms. The PMIC is connected to the host processor via SPMI bus. 27, 29, 32, 35. default: 29V This property is supported only for PM8941. +- qcom,ovp-millivolt + Usage: optional + Value type: <u32> + Definition: mV; Over-voltage protection limit; + For pmi8998: one of 18100, 19600, 29600, 31100 + Default: 29600 mV + If this property is not specified for PM8941, it + falls back to "qcom,ovp" property. + - qcom,num-strings Usage: optional Value type: <u32> Definition: #; number of led strings attached; - value from 1 to 3. default: 2 - This property is supported only for PM8941. + value: For PM8941 from 1 to 3. default: 2 + For PMI8998 from 1 to 4. default: 4 + +- interrupts + Usage: optional + Value type: <prop encoded array> + Definition: Interrupts associated with WLED. This should be + "short" and "ovp" interrupts. Interrupts can be + specified as per the encoding listed under + Documentation/devicetree/bindings/spmi/ + qcom,spmi-pmic-arb.txt. + +- interrupt-names + Usage: optional + Value type: <string> + Definition: Interrupt names associated with the interrupts. + Must be "short" and "ovp". The short circuit detection + is not supported for PM8941. + +- qcom,enabled-strings + Usage: optional + Value tyoe: <u32 array> + Definition: Array of the WLED strings numbered from 0 to 3. Each + string of leds are operated individually. Specify the + list of strings used by the device. Any combination of + led strings can be used. + for pm8941: Default values are [00 01]. + for pmi8998: Default values are [00 01 02 03]. + +- qcom,external-pfet + Usage: optional + Value type: <bool> + Definition: Specify if external PFET control for short circuit + protection is used. This property is supported only + for PMI8998. + +- qcom,auto-string-detection + Usage: optional + Value type: <bool> + Definition: Enables auto-detection of the WLED string configuration. + This feature is not supported for PM8941. + Example: @@ -99,4 +152,21 @@ pm8941-wled@d800 { qcom,switching-freq = <1600>; qcom,ovp = <29>; qcom,num-strings = <2>; + qcom,enabled-strings = <0x00 0x01>; +}; + +pmi8998-wled@d800 { + compatible = "qcom,pmi8998-wled"; + reg = <0xd800 0xd900>; + label = "backlight"; + + interrupts = <3 0xd8 2 IRQ_TYPE_EDGE_RISING>, + <3 0xd8 1 IRQ_TYPE_EDGE_RISING>; + interrupt-names = "short", "ovp"; + qcom,current-limit-microamp = <25000>; + qcom,current-boost-limit = <805>; + qcom,switching-freq = <1600>; + qcom,ovp-millivolt = <29600>; + qcom,num-strings = <4>; + qcom,enabled-strings = <0x00 0x01 0x02 0x03>; }; -- The Qualcomm Innovation Center, Inc. is a member of the Code Aurora Forum, a Linux Foundation Collaborative Project _______________________________________________ dri-devel mailing list dri-devel@xxxxxxxxxxxxxxxxxxxxx https://lists.freedesktop.org/mailman/listinfo/dri-devel