Re: [PATCH v4 1/3] drm/panel: refactor INNOLUX P079ZCA panel driver

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Hi Emil,


On Monday, March 19, 2018 09:09 PM, Emil Velikov wrote:
On 15 March 2018 at 02:35, hl <hl@xxxxxxxxxxxxxx> wrote:
Hi Emil,



On Wednesday, March 14, 2018 08:02 PM, Emil Velikov wrote:
Hi Lin,

On 14 March 2018 at 09:12, Lin Huang <hl@xxxxxxxxxxxxxx> wrote:
From: huang lin <hl@xxxxxxxxxxxxxx>

Refactor Innolux P079ZCA panel driver, let it support
multi panel.

Change-Id: If89be5e56dba8cb498e2d50c1bbeb0e8016123a2
Signed-off-by: Lin Huang <hl@xxxxxxxxxxxxxx>
---
Changes in v2:
- Change regulator property name to meet the panel datasheet
Changes in v3:
- this patch only refactor P079ZCA panel to support multi panel, support
P097PFG panel in another patch
Changes in v4:
- Modify the patch which suggest by Thierry

Thanks for splitting this up. I think there's another piece that fell
through the cracks.
I'm not deeply familiar with the driver, so just sharing some quick notes.


   struct innolux_panel {
          struct drm_panel base;
          struct mipi_dsi_device *link;
+       const struct panel_desc *desc;

          struct backlight_device *backlight;
-       struct regulator *supply;
+       struct regulator *vddi;
+       struct regulator *avdd;
+       struct regulator *avee;
These two seem are new addition, as opposed to a dummy refactor.
Are they optional, does one need them for the existing panel (separate
patch?) or only for the new one (squash with the new panel code)?


          struct gpio_desc *enable_gpio;

          bool prepared;
@@ -77,9 +93,9 @@ static int innolux_panel_unprepare(struct drm_panel
*panel)
          /* T8: 80ms - 1000ms */
          msleep(80);

-       err = regulator_disable(innolux->supply);
-       if (err < 0)
-               return err;
Good call on dropping the early return here.


@@ -207,19 +248,28 @@ static const struct drm_panel_funcs
innolux_panel_funcs = {
-       innolux->supply = devm_regulator_get(dev, "power");
-       if (IS_ERR(innolux->supply))
-               return PTR_ERR(innolux->supply);
+       innolux = devm_kzalloc(dev, sizeof(*innolux), GFP_KERNEL);
+       if (!innolux)
+               return -ENOMEM;
+
+       innolux->desc = desc;
+       innolux->vddi = devm_regulator_get(dev, "power");
+       innolux->avdd = devm_regulator_get(dev, "avdd");
+       innolux->avee = devm_regulator_get(dev, "avee");

AFAICT devm_regulator_get returns a pointer which is unsuitable to be
passed into regulator_{enable,disable}.
Hence, the IS_ERR check should stay. If any of the regulators are
optional, you want to call regulator_{enable,disable} only as
applicable.

devm_regulator_get() will use dummy_regulator if there not regulator pass to
driver, so it not affect regulator_{enable, disable}.
One of us is getting confused here:
devm_regulator_get does not _use_ a regulator, it returns a pointer to
a regulator, right?

According to the 4.16-rc6 codebase - one error
returns a ERR_PTR [1].
devm_regulator_get() will not reurn a ERR_PTR,  it will pass NORMAL_GET mode to _regulator_get() when you call devm_regulator_get(), and with following code:


rdev = regulator_dev_lookup(dev, id);
    if (IS_ERR(rdev)) {
.....
......
    switch (get_type) {
        case NORMAL_GET:
            /*
             * Assume that a regulator is physically present and
             * enabled, even if it isn't hooked up, and just
             * provide a dummy.
             */
            dev_warn(dev,
                 "%s supply %s not found, using dummy regulator\n",
                 devname, id);
            rdev = dummy_regulator_rdev;
            get_device(&rdev->dev);
            break;
...
...
}
....
regulator = create_regulator(rdev, dev, id);
...

it wil get a dummy_regulator for it.



With the pointer dereferenced in regulator_enable [2], without a
IS_ERR check, hence thing will go boom(?)

These three regulator are
optional,
the p079zca will use "power" and ,
so i think it better not to check ERR here.

What should happen if p079zca is missing "power" or p097pgf - "avdd" and "avee"?
Obviously the latter two should be introduced with the p097pgf support.
i think it need dts to make sure configure the power node correct, if missing
"power" node fo p079zca or "avdd" "avee" node for p097pgf, the panel can
not work, but do not affcet other driver, the kernel do not crash(as i explain before and i also test it).

HTH
Emil

[1] https://elixir.bootlin.com/linux/v4.16-rc6/source/drivers/regulator/devres.c#L27
[2] https://elixir.bootlin.com/linux/v4.16-rc6/source/drivers/regulator/core.c#L2189





_______________________________________________
dri-devel mailing list
dri-devel@xxxxxxxxxxxxxxxxxxxxx
https://lists.freedesktop.org/mailman/listinfo/dri-devel




[Index of Archives]     [Linux DRI Users]     [Linux Intel Graphics]     [Linux USB Devel]     [Video for Linux]     [Linux Audio Users]     [Yosemite News]     [Linux Kernel]     [Linux SCSI]     [XFree86]     [Linux USB Devel]     [Video for Linux]     [Linux Audio Users]     [Linux Kernel]     [Linux SCSI]     [XFree86]