Re: [PATCH 4/4] drm/pl111: Support multiple endpoints on the CLCD

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Linus Walleij <linus.walleij@xxxxxxxxxx> writes:

> The Versatile PL110 implementations use multiple endpoints:
> from the PL111 port, the lines are routed through a PLD,
> and from there forked so the same lines go to a VGA DAC and
> an external TFT panel connector. This is discrete wireing
> so there is no way to turn of one output, i.e. this is
> really two endpoints, not two ports.
>
> We model this with multiple endpoints, so we need to loop
> over the available endpoints, check for panel or bridge on
> each and accumulate the result before continuing.
>
> The code already will give the panel preference over the
> bridge, if present, so the output will be sent to the panel
> if both a panel and a bridge is present on two endpoints
> of the same port.
>
> If they all return -EPROBE_DEFER we return -EPROBE_DEFER
> as well.
>
> If just one endpoint is present on the port, the behaviour
> is the same as before.
>
> Signed-off-by: Linus Walleij <linus.walleij@xxxxxxxxxx>

Huh, from the binding I would have thought that we were describing
things to the point of the pins coming out of the PLD, not past whatever
splitting comes after that.

I'm also confused how this would work.  You're talking about the DT
looking like:

	clcd@10020000 {
		compatible = "arm,pl111", "arm,primecell";
		reg = <0x10020000 0x1000>;
		interrupt-names = "combined";
		interrupts = <0 44 4>;
		clocks = <&oscclk1>, <&oscclk2>;
		clock-names = "clcdclk", "apb_pclk";
		max-memory-bandwidth = <94371840>; /* Bps, 1024x768@60 16bpp */

		port {
			dac_pads: endpoint1 {
				remote-endpoint = <&vgadac>;
				arm,pl11x,tft-r0g0b0-pads = <0 8 16>;
			};
			tft_pads: endpoint2 {
				remote-endpoint = <&tftpanel>;
				arm,pl11x,tft-r0g0b0-pads = <0 8 16>;
			};
		};

	};


Are you anticipating that a DT would actually connect up to two
endpoints on the CLCD?  How should we resolve the pads property, in that
case?  Is there much point in supporting this, if we don't actually
support panels or bridges on both of the endpoints at once (since we
pick only one to do panel/bridge setup/teardown on)?

Attachment: signature.asc
Description: PGP signature

_______________________________________________
dri-devel mailing list
dri-devel@xxxxxxxxxxxxxxxxxxxxx
https://lists.freedesktop.org/mailman/listinfo/dri-devel

[Index of Archives]     [Linux DRI Users]     [Linux Intel Graphics]     [Linux USB Devel]     [Video for Linux]     [Linux Audio Users]     [Yosemite News]     [Linux Kernel]     [Linux SCSI]     [XFree86]     [Linux USB Devel]     [Video for Linux]     [Linux Audio Users]     [Linux Kernel]     [Linux SCSI]     [XFree86]