On 8/23/22 05:18, Pankaj Raghav wrote:
Remove the condition which disallows non-power_of_2 zone size ZNS drive to be updated and use generic method to calculate number of zones instead of relying on log and shift based calculation on zone size. The power_of_2 calculation has been replaced directly with generic calculation without special handling. Both modified functions are not used in hot paths, they are only used during initialization & revalidation of the ZNS device. As rounddown macro from math.h does not work for 32 bit architectures, round down operation is open coded.
Reviewed-by: Bart Van Assche <bvanassche@xxxxxxx> -- dm-devel mailing list dm-devel@xxxxxxxxxx https://listman.redhat.com/mailman/listinfo/dm-devel