Hi, We have a SLES 11 SP1 running with following snippet in multpath.conf ########################## device { vendor "IBM" product "1818" path_grouping_policy group_by_prio prio rdac getuid_callout "/lib/udev/scsi_id -g -u -d /dev/%n" polling_interval 5 path_checker rdac path_selector "round-robin 0" hardware_handler "1 rdac" failback immediate features "2 pg_init_retries 50" no_path_retry 30 rr_min_io 100 } ################################# But when we see "multipath -ll" output we see: mpathca (3600a0b8000475c52000006a04b60f1d9) dm-38 IBM,1818 FAStT size=2.0G features='3 queue_if_no_path pg_init_retries 50' hwhandler='1 rdac' wp=rw |-+- policy='round-robin 0' prio=6 status=active | |- 4:0:5:1 sdcz 70:112 active ready running | `- 5:0:5:1 sddl 71:48 active ready running `-+- policy='round-robin 0' prio=1 status=enabled |- 4:0:4:1 sdcx 70:80 active ghost running `- 5:0:3:1 sddh 70:240 active ghost running So, my question is : even if we mention features "2 pg_init_retries 50" why are we seeing " features='3 queue_if_no_path pg_init_retries 50' hwhandler='1 rdac' wp=rw" in the multipath -ll output ? 1) Where is this "3" coming from ? and what is it's significance ?? 2) Is this "3" next to the features in "multipath -ll" output as expected (even though we mention "2 pg_init_retries 50" ) in our multipath.conf ?? (We've rebooted and regenerated multipath maps multiple times by "multipath -F" and then "multipath" )....but we still see this "discrepancy" (of "2" vs "3") ? Will appreciate if someone can explain us. Thanks, Dharmesh. -- dm-devel mailing list dm-devel@xxxxxxxxxx https://www.redhat.com/mailman/listinfo/dm-devel