On Thu, Feb 5, 2009 at 4:07 PM, Bryn M. Reeves <bmr@xxxxxxxxxx> wrote:
Christian Røsnes wrote:

u should check what the MD3000i reports in sysfs. E.g. for an EMC
clariion device I see:

# cat /sys/block/sdj/device/vendor
DGC
# cat /sys/block/sdj/device/model
RAID 5

And the corresponding entry in multipath.conf is:

              vendor                  "DGC"
              product                 "*"

I suspect from the output below that you want:

              vendor                  "DELL"
              product                 "DELL,MD Virtual Disk"


Here's what I see for the MD3000i:

# cat /sys/block/sdb/device/vendor
DELL
# cat /sys/block/sdb/device/model
MD Virtual Disk
 
Thank you
Christian

--