Hi Malahal, malahal@xxxxxxxxxx wrote: >> Avoiding disk replication even if a log device got trouble is one of >> the requirements. Is there any solution to avoid this problem by the >> mirrored log approach? > > Two ways to fix: > 1) Never make "error leg" as your master leg as that is pointless. > 2) Maybe we can use 'nosync' option when one of the two legs is known to > be an error device. This is probably easier than method (1) > > Any other methods? Any help regarding which method to pursue would be > very much appreciated. > > Thanks, Malahal. > PS: This patch was always used along with other patches and that could > explain why we didn't notice this problem. If I understand Takahiro correctly, the main issue is that the whole log device becomes unusable in case one leg is broken...? Of course, we still have the other leg with the most recent data available and can read from that one. However, this would require that we can start a mirror in rw-mode (so we can keep the still-recent half up to date) even if one half has failed - a functionality which was recently added to LVM, as we discussed in our last call...? I'm not sure if I understand his statements about the synchronization correctly. Why would any synchronization within the data mirror occur at all? It's only the log which is broken, not the actual data in vg00-lv00_mimage_0/1. If any synchronization in the _data_ mirror occurs just because one leg in the _log_ mirror has a problem, I'd consider that a bug. Ciao, Stefan -- Linux on System z IBM Deutschland Research & Development GmbH Vorsitzender des Aufsichtsrats: Martin Jetter Geschäftsführer: Erich Baier Sitz der Gesellschaft: Böblingen Registergericht: Amtsgericht Stuttgart, HRB 243294 -- dm-devel mailing list dm-devel@xxxxxxxxxx https://www.redhat.com/mailman/listinfo/dm-devel