I am testing SLES 9 SP3 with an EMC CLARiiON array (CX300). When I pull cables (on the storage side of the switches) the IO's are successfully switched to the good paths (all the way down to a single good path). However when I replace the cables the switchback does not seem to work successfully. Well, for the active devices, e.g. where there are IO's being issued, everything seems to work fine. For devices that are not being used there lots of messages (every loop of multipathd). I see the message: multipathd: 360060160cfd0150045435fc76f20da11: switch to path group #1 and then device-mapper: dm-emc: emc_pg_init: sending switch-over command Then it repeats the switch to path group messages (each iteration of the multipathd daemon). This seems to repeat indefinitely. There are no other messages that would indicate a failure or problem. The output from multipath -ll shows everything is now active/ready: 360060160cfd0150045435fc76f20da11 [size=5 GB][features="1 queue_if_no_path"][hwhandler="1 emc"] \_ round-robin 0 [prio=2][enabled] \_ 2:0:1:16 sdbz 68:208 [active][ready] \_ 1:0:0:16 sdr 65:16 [active][ready] \_ round-robin 0 [enabled] \_ 1:0:1:16 sdal 66:80 [active][ready] \_ 2:0:0:16 sdbf 67:144 [active][ready] The multipath.conf entry is: device { vendor "DGC" product "*" path_grouping_policy group_by_prio getuid_callout "/sbin/scsi_id -g -u -s /block/%n" prio_callout "/sbin/mpath_prio_emc /dev/%n" hardware_handler "1 emc" features "1 queue_if_no_path" path_checker emc_clariion failback immediate } If I startup IO to the luns that are being complained about the messages stop. It does not seem the switchover is performed unless there is IO happening at the time the switchover is attempted. Eddie -- dm-devel@xxxxxxxxxx https://www.redhat.com/mailman/listinfo/dm-devel