On 17/03/2025 17:44, Dmitry Baryshkov wrote:
nit: Subject:
s/qcom,coresight-static-replicator/arm,coresight-static-replicator
As most other CoreSight devices the replicator can use either of the
optional clocks (or both). Document those optional clocks in the schema.
Fixes: 3c15fddf3121 ("dt-bindings: arm: Convert CoreSight bindings to DT schema")
Signed-off-by: Dmitry Baryshkov <dmitry.baryshkov@xxxxxxxxxxxxxxxx>
---
.../bindings/arm/arm,coresight-static-replicator.yaml | 10 ++++++++++
1 file changed, 10 insertions(+)
diff --git a/Documentation/devicetree/bindings/arm/arm,coresight-static-replicator.yaml b/Documentation/devicetree/bindings/arm/arm,coresight-static-replicator.yaml
index a6f793ea03b6c193fc0ff72a45e0249a63a2ba3c..56e64067ed3d63c5e293a0840858f13428bacb45 100644
--- a/Documentation/devicetree/bindings/arm/arm,coresight-static-replicator.yaml
+++ b/Documentation/devicetree/bindings/arm/arm,coresight-static-replicator.yaml
@@ -30,6 +30,16 @@ properties:
power-domains:
maxItems: 1
+ clocks:
+ minItems: 1
+ maxItems: 2
+
For the static replicator, you don't have an APB clock, as they can't be
programmed. It may have an ATB clock. So minItems 0, maxItems: 1
Suzuki
+ clock-names:
+ minItems: 1
+ enum:
+ - apb_pclk
+ - atclk
+
in-ports:
$ref: /schemas/graph.yaml#/properties/ports
additionalProperties: false