From: ChiYuan Huang <cy_huang@xxxxxxxxxxx> Since the check for fixed LDO VOUT can be identified by the HW register, mark the unnecessary property as deprecated. Signed-off-by: ChiYuan Huang <cy_huang@xxxxxxxxxxx> --- Hi, By Mark's comment, not to affect the old DT buggy, so mark this property as deprecated. It's better than to directly remove it. --- .../devicetree/bindings/regulator/richtek,rtq2208.yaml | 3 ++- 1 file changed, 2 insertions(+), 1 deletion(-) diff --git a/Documentation/devicetree/bindings/regulator/richtek,rtq2208.yaml b/Documentation/devicetree/bindings/regulator/richtek,rtq2208.yaml index 87accc6f13b8..022c1f197364 100644 --- a/Documentation/devicetree/bindings/regulator/richtek,rtq2208.yaml +++ b/Documentation/devicetree/bindings/regulator/richtek,rtq2208.yaml @@ -39,7 +39,7 @@ properties: interrupts: maxItems: 1 - + richtek,mtp-sel-high: type: boolean description: @@ -77,6 +77,7 @@ properties: properties: richtek,fixed-microvolt: + deprecated: true description: | This property can be used to set a fixed operating voltage that lies outside the range of the regulator's adjustable mode. -- 2.34.1