Hi Lee, On Thu, 07 May 2015, Lee Jones wrote: > This IP is shared with Watchdog and RTC functionality. Only one of > these IPs can be used at the same time. We use the device-driver > model combined with a DT 'mode' property to enforce this. Which means my previous assertion in V1 that the IP didn't exist on stih415/6 SoC is most likely wrong, as the watchdog driver has bindings already for those platforms. I did try this before and couldn't get it working (driver failed on clk_get_rate) on stih416-b2020. Did you try and see if you can get this also working for stih415/6 SoCs? It would mean we can move away from arm_global_timer for all upstreamed STI platforms. regards, Peter. -- To unsubscribe from this list: send the line "unsubscribe devicetree" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html