On Thu, 2025-02-20 at 15:54 +0200, Antoniu Miclaus wrote: > Add documentation for the ad4080 attributes. > > Signed-off-by: Antoniu Miclaus <antoniu.miclaus@xxxxxxxxxx> > --- > .../ABI/testing/sysfs-bus-iio-adc-ad4080 | 55 +++++++++++++++++++ > 1 file changed, 55 insertions(+) > create mode 100644 Documentation/ABI/testing/sysfs-bus-iio-adc-ad4080 > > diff --git a/Documentation/ABI/testing/sysfs-bus-iio-adc-ad4080 > b/Documentation/ABI/testing/sysfs-bus-iio-adc-ad4080 > new file mode 100644 > index 000000000000..e37bfba0e989 > --- /dev/null > +++ b/Documentation/ABI/testing/sysfs-bus-iio-adc-ad4080 > @@ -0,0 +1,55 @@ > +What: /sys/bus/iio/devices/iio:deviceX/lvds_sync > +Date: February 2025 > +KernelVersion: > +Contact: linux-iio@xxxxxxxxxxxxxxx > +Description: > + This attribute handles the data synchronization > process.Because the CNV > + signal is not taken into account by the FPGA when capturing > the data, we > + need a process that configures the ADC to output pattern > data, writes the > + SYNC bit in the axi_adc register map, waits until the custom > HDL syncs the > + data correctly, and then changes the output mode to analog > data instead of > + the fixed pattern. I'll comment this one in the driver. I have some questions on how this works... > + > +What: /sys/bus/iio/devices/iio:deviceX/lvds_lvds > +Date: February 2025 > +KernelVersion: > +Contact: linux-iio@xxxxxxxxxxxxxxx > +Description: > + Configures the signal type of the CNV signal. The value can > be either CMOS > + (lvds_cnv=0) or LVDS (lvds_cnv=1). The name seems to be wrong with what you have implemented. From this description, I would think of this as a DT property? Can the signal type really change at runtime? > + > +What: /sys/bus/iio/devices/iio:deviceX/filter_sel > +Date: February 2025 > +KernelVersion: > +Contact: linux-iio@xxxxxxxxxxxxxxx > +Description: > + This attribute enables the digital filter functionality of > the AD4080.In > + order to capture data correctly, the function must configure > the ADC > + through SPI to select the filter type and enable data capture > in filter > + mode through axi_adc(In this mode, data is gated by a signal > generated by > + the AD4080 (GPIO1 and is not continuous as it is when the > filter is > + disabled). > + > +What: /sys/bus/iio/devices/iio:deviceX/filter_sel_available > +Date: February 2025 > +KernelVersion: > +Contact: linux-iio@xxxxxxxxxxxxxxx > +Description: > + Return the available filter modes that can be set. There's a standard attr for this. I think we settled > + > +What: /sys/bus/iio/devices/iio:deviceX/sinc_dec_rate > +Date: February 2025 > +KernelVersion: > +Contact: linux-iio@xxxxxxxxxxxxxxx > +Description: > + Set the filter’s decimation rate. > + > +What: /sys/bus/iio/devices/iio:deviceX/sinc_dec_rate_available > +Date: February 2025 > +KernelVersion: > +Contact: linux-iio@xxxxxxxxxxxxxxx > +Description: > + Return the available filter's decimation rates. > + > + I'm not yet convinced we need the dec_rate custom attr. I'll add more comments in the driver. - Nuno Sá