On 12.02.2025 12:33 PM, Rakesh Kota wrote: > Add support for vadc and adc-tm channels which are used for > monitoring thermistors present on the platform. > > - Add the necessary includes for qcom,spmi-adc7-pm7325 and > qcom,spmi-adc7-pmk8350. > - Add thermal zones for quiet-thermal, sdm-skin-thermal, and > xo-thermal, and define their polling delays and thermal sensors. > - Configure the pm7325_temp_alarm node to use the pmk8350_vadc > channel for thermal monitoring. > - Configure the pmk8350_adc_tm node to enable its thermal sensors > and define their registers and settings. > - Configure the pmk8350_vadc node to define its channels and settings > > Signed-off-by: Rakesh Kota <quic_kotarake@xxxxxxxxxxx> > --- > Changes from V2: > - As per Konrad Dybcio’s suggestion, removed all default polling values. > Changes from V1: > - Update the Die temp name to Channel as per Documentation. > - As per Konrad Dybcio’s suggestion, I have sorted the pmk8350_adc_tm > channels by unit address instead of alphabetically. > --- Reviewed-by: Konrad Dybcio <konrad.dybcio@xxxxxxxxxxxxxxxx> Konrad