On 02/01/2025 18:50, Peter Korsgaard wrote: > The pwm-fan driver uses full PWM (255) duty cycle at startup, which may not > always be desirable because of noise or power consumption peaks, so add an > optional "default-pwm" property that can be used to specify a custom default > PWM duty cycle. > > Signed-off-by: Peter Korsgaard <peter@xxxxxxxxxxxxx> That's v3, not v1. Also mention here shortly how Rob's comment is addressed. Please always handle reviewers' feedback, either by implementing it or by responding or by extending commit msg. All this is missing in all your versions you sent. Best regards, Krzysztof