On Wed, 18 Dec 2024 09:34:59 +0100, Dimitri Fedrau wrote: > With DT properties charge-current-limit-gpios and > charge-current-limit-mapping one can define charge current limits in uA > using up to 32 GPIOs. At the moment the driver defaults to smallest charge > current limitation for safety reasons. When disabling charging is > supported, which should be common, the driver defaults to non charging on > probe. By having a default, charging can be enabled on probe for such > devices. > > [...] Applied, thanks! [1/2] dt-bindings: power: supply: gpio-charger: add support for default charge current limit commit: 0a219d6fd7ab89177a6fa49539def43694154d50 [2/2] power: supply: gpio-charger: add support for default charge current limit commit: de68987480cb92702eab14cf62ec2aa1bae5c867 Best regards, -- Sebastian Reichel <sebastian.reichel@xxxxxxxxxxxxx>