From: Thomas Antoine <t.antoine@xxxxxxxxxxxx> As the Maxim max77759 fuel gauge has no non-volatile memory slave address, make it non-obligatory. Except for this, the max77759 seems to behave the same as the max1720x. Signed-off-by: Thomas Antoine <t.antoine@xxxxxxxxxxxx> --- .../devicetree/bindings/power/supply/maxim,max17201.yaml | 14 ++++++++++++++ 1 file changed, 14 insertions(+) diff --git a/Documentation/devicetree/bindings/power/supply/maxim,max17201.yaml b/Documentation/devicetree/bindings/power/supply/maxim,max17201.yaml index fe3dd9bd5585618e45220c51023391a5b21acfd2..417fc2c4a1c1961654bc54ec1ac24602012f3335 100644 --- a/Documentation/devicetree/bindings/power/supply/maxim,max17201.yaml +++ b/Documentation/devicetree/bindings/power/supply/maxim,max17201.yaml @@ -16,6 +16,7 @@ properties: compatible: oneOf: - const: maxim,max17201 + - const: maxim,max77759-fg - items: - enum: - maxim,max17205 @@ -25,11 +26,13 @@ properties: items: - description: ModelGauge m5 registers - description: Nonvolatile registers + minItems: 1 reg-names: items: - const: m5 - const: nvmem + minItems: 1 interrupts: maxItems: 1 @@ -56,3 +59,14 @@ examples: interrupts = <31 IRQ_TYPE_LEVEL_LOW>; }; }; + - | + i2c { + #address-cells = <1>; + #size-cells = <0>; + + fuel-gauge@36 { + compatible = "maxim,max77759-fg"; + reg = <0x36>; + reg-names = "m5"; + }; + }; -- 2.47.1