Re: [PATCH v3 1/2] dt-bindings: hwmon: pwm-fan: Document start from stopped state properties

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On Wed, Nov 06, 2024 at 07:59:04PM +0100, Marek Vasut wrote:
> Delta AFC0612DB-F00 fan has to be set to at least 30% PWM duty cycle
> to spin up from a stopped state, and can be afterward throttled down to
> lower PWM duty cycle. Introduce support for operating such fans which
> need to start at higher PWM duty cycle first and can slow down next.
> 
> Document two new DT properties, "fan-stop-to-start-percent" and
> "fan-stop-to-start-usec". The former describes the minimum percent
> of fan RPM at which it will surely spin up from stopped state. This
> value can be found in the fan datasheet and can be converted to PWM
> duty cycle easily. The "fan-stop-to-start-usec" describes the minimum
> time in microseconds for which the fan has to be set to stopped state
> start RPM for the fan to surely spin up.
> 
> Signed-off-by: Marek Vasut <marex@xxxxxxx>
> Acked-by: Conor Dooley <conor.dooley@xxxxxxxxxxxxx>

Applied.

Thanks,
Guenter




[Index of Archives]     [Device Tree Compilter]     [Device Tree Spec]     [Linux Driver Backports]     [Video for Linux]     [Linux USB Devel]     [Linux PCI Devel]     [Linux Audio Users]     [Linux Kernel]     [Linux SCSI]     [XFree86]     [Yosemite Backpacking]


  Powered by Linux