On 11/5/24 17:28, Marek Vasut wrote:
On 11/6/24 1:34 AM, Guenter Roeck wrote:
On 11/5/24 10:53, Marek Vasut wrote:
On 11/5/24 3:11 PM, Guenter Roeck wrote:
On 11/5/24 05:52, Marek Vasut wrote:
Delta AFC0612DB-F00 fan has to be set to at least 30% PWM duty cycle
to spin up from a dead stop, and can be afterward throttled down to
lower PWM duty cycle. Introduce support for operating such fans which
Doesn't this imply that a minimum pwm value is needed as well ?
It depends. For this fan, yes, it does stop at around 8% PWM duty cycle.
Super-IO chips such as the NCT67xx series typically have two separate
registers, one for the pwm start value and one for the minimum pwm value.
I use plain SoC PWM output to operate the fan. This one needs to be set to higher PWM duty cycle first, to spin up, and can be reduced to lower PWM duty cycle afterward without stopping.
Yes, exactly. That is what many fans require.
need to start at higher PWM duty cycle first and can slow down next.
Document two new DT properties, "fan-dead-stop-start-percent" and
"fan-dead-stop-start-usec". The former describes the minimum percent
of fan RPM at which it will surely spin up from dead stop. This value
can be found in the fan datasheet and can be converted to PWM duty
cycle easily. The "fan-dead-stop-start-usec" describes the minimum
time in microseconds for which the fan has to be set to dead stop
start RPM for the fan to surely spin up.
Signed-off-by: Marek Vasut <marex@xxxxxxx>
---
Cc: Conor Dooley <conor+dt@xxxxxxxxxx>
Cc: Guenter Roeck <linux@xxxxxxxxxxxx>
Cc: Jean Delvare <jdelvare@xxxxxxxx>
Cc: Krzysztof Kozlowski <krzk+dt@xxxxxxxxxx>
Cc: Rob Herring <robh@xxxxxxxxxx>
Cc: devicetree@xxxxxxxxxxxxxxx
Cc: linux-hwmon@xxxxxxxxxxxxxxx
---
Documentation/devicetree/bindings/hwmon/pwm-fan.yaml | 11 +++++++++++
1 file changed, 11 insertions(+)
diff --git a/Documentation/devicetree/bindings/hwmon/pwm-fan.yaml b/ Documentation/devicetree/bindings/hwmon/pwm-fan.yaml
index 4e5abf7580cc6..f1042471b5176 100644
--- a/Documentation/devicetree/bindings/hwmon/pwm-fan.yaml
+++ b/Documentation/devicetree/bindings/hwmon/pwm-fan.yaml
@@ -31,6 +31,17 @@ properties:
it must be self resetting edge interrupts.
maxItems: 1
+ fan-dead-stop-start-percent:
Personally I don't think that "dead-stop" in the property name adds any value.
On the contrary, I think it leads to confusion. I head to read the description
to understand.
The documentation refers to this behavior as a "dead stop" , hence the property name. I can change it to fan-stop-to-start-percent ?
I do not understand the need for that much complexity in the property name,
and I don't think it makes sense to name a property based on a specific
chip documentation. I have seen that before, where different vendors use
different names for the same functionality. That doesn't mean that the
vendor-determined name has to make it into the property name.
As an example, Nuvoton calls the values "Start-Up Value" and "Stop Value".
ITE calls the start value "start PWM value" (and as far as I can see doesn't
have a separate stop value). I am sure pretty much every vendor uses a
different description.
I am personally not a friend of long property names. Having said that,
I'll let you use whatever DT maintainers accept. They may have a different
opinion.
Do you have a different suggestion for the property name ? Else I'll just send a V2 .
fan-start-percent and fan-stop-percent would be good enough for me.
However, the existing cooling-levels property uses duty cycle values
from 0 ..255. Using % for the new properties will create an inconsistency.
It will be up to DT maintainers to decide how the properties should be
defined.
Guenter