On 4.11.2024 1:44 PM, Manikanta Mylavarapu wrote: > Add thermal zone nodes for sensors present in IPQ5424. > > Signed-off-by: Manikanta Mylavarapu <quic_mmanikan@xxxxxxxxxxx> > --- [...] > + > + cpu3-thermal { > + polling-delay-passive = <0>; > + polling-delay = <0>; > + thermal-sensors = <&tsens 13>; > + > + trips { > + cpu-critical { > + temperature = <120000>; > + hysteresis = <9000>; > + type = "critical"; > + }; > + > + cpu-passive { > + temperature = <110000>; > + hysteresis = <9000>; > + type = "passive"; You have a passive trip point without passive polling > + }; > + }; > + }; > + > + wcss-tile2-thermal { > + polling-delay-passive = <0>; > + polling-delay = <0>; These are the defaults > + thermal-sensors = <&tsens 9>; > + > + trips { > + wcss_tile2-critical { Node names must not contain underscores Konrad