In order to access the registers of the HW, we need to make sure that the AXI bus clock is enabled. Hence let's increase the number of clocks by one and add clock-names to differentiate between parent clocks and the bus clock. Fixes: 0e646c52cf0e ("clk: Add axi-clkgen driver") Signed-off-by: Nuno Sa <nuno.sa@xxxxxxxxxx> --- .../devicetree/bindings/clock/adi,axi-clkgen.yaml | 22 ++++++++++++++++++---- 1 file changed, 18 insertions(+), 4 deletions(-) diff --git a/Documentation/devicetree/bindings/clock/adi,axi-clkgen.yaml b/Documentation/devicetree/bindings/clock/adi,axi-clkgen.yaml index 5e942bccf27787d7029f76fc1a284232fb7f279d..2b2041818a0a44456ee986fe29d32346f68835f3 100644 --- a/Documentation/devicetree/bindings/clock/adi,axi-clkgen.yaml +++ b/Documentation/devicetree/bindings/clock/adi,axi-clkgen.yaml @@ -26,9 +26,21 @@ properties: description: Specifies the reference clock(s) from which the output frequency is derived. This must either reference one clock if only the first clock - input is connected or two if both clock inputs are connected. - minItems: 1 - maxItems: 2 + input is connected or two if both clock inputs are connected. The last + clock is the AXI bus clock that needs to be enabled so we can access the + core registers. + minItems: 2 + maxItems: 3 + + clock-names: + oneOf: + - items: + - const: clkin1 + - const: s_axi_aclk + - items: + - const: clkin1 + - const: clkin2 + - const: s_axi_aclk '#clock-cells': const: 0 @@ -40,6 +52,7 @@ required: - compatible - reg - clocks + - clock-names - '#clock-cells' additionalProperties: false @@ -50,5 +63,6 @@ examples: compatible = "adi,axi-clkgen-2.00.a"; #clock-cells = <0>; reg = <0xff000000 0x1000>; - clocks = <&osc 1>; + clocks = <&osc 1>, <&clkc 15>; + clock-names = "clkin1", "s_axi_aclk"; }; -- 2.47.0