On 15/10/2024 13:33, Naresh Solanki wrote: > Add bindings for Vicor pli1209bc. > It a Digital Supervisor with Isolation for use with BCM Bus Converter > Modules. > > Signed-off-by: Naresh Solanki <naresh.solanki@xxxxxxxxxxxxx> > --- > .../bindings/hwmon/pmbus/vicor,pli1209bc.yaml | 65 +++++++++++++++++++ This has to be squashed with previous patch. > 1 file changed, 65 insertions(+) > create mode 100644 Documentation/devicetree/bindings/hwmon/pmbus/vicor,pli1209bc.yaml > > diff --git a/Documentation/devicetree/bindings/hwmon/pmbus/vicor,pli1209bc.yaml b/Documentation/devicetree/bindings/hwmon/pmbus/vicor,pli1209bc.yaml > new file mode 100644 > index 000000000000..3647d14e9111 > --- /dev/null > +++ b/Documentation/devicetree/bindings/hwmon/pmbus/vicor,pli1209bc.yaml > @@ -0,0 +1,65 @@ > +# SPDX-License-Identifier: (GPL-2.0 OR BSD-2-Clause) > +%YAML 1.2 > +--- > + Drop blank line > +$id: http://devicetree.org/schemas/hwmon/pmbus/vicor,pli1209bc.yaml# > +$schema: http://devicetree.org/meta-schemas/core.yaml# > + > +title: Vicor PLI1209BC Power Regulator > + > +maintainers: > + - Marcello Sylvester Bauer <sylv@xxxxxxx> > + - Naresh Solanki <naresh.solanki@xxxxxxxxxxxxx> > + > +description: | Do not need '|' unless you need to preserve formatting. > + The Vicor PLI1209BC is a Digital Supervisor with Isolation for use > + with BCM Bus Converter Modules. > + > +properties: > + compatible: > + enum: > + - vicor,pli1209bc > + > + reg: > + maxItems: 1 > + > + regulators: Drop the node and define vout2 here directly.... unless anything needs such layout? Then explain this in commit msg. > + type: object > + description: > + List of regulators provided by this controller. > + > + properties: > + vout2: > + $ref: /schemas/regulator/regulator.yaml# > + type: object > + Drop blank line. > + unevaluatedProperties: false > + > + additionalProperties: false > + > +required: > + - compatible > + - reg > + > +additionalProperties: false > + > +examples: > + - | > + #include <dt-bindings/interrupt-controller/irq.h> Drop, not used. > + i2c { > + #address-cells = <1>; > + #size-cells = <0>; > + > + pli1209bc_p12v_d: regulator@5f { Drop unused prefix > + compatible = "vicor,pli1209bc"; > + reg = <0x5f>; > + > + regulators { > + p12v_d: vout2 { > + regulator-name = "bcm3"; > + regulator-boot-on; > + }; > + }; > + }; > + }; > + Best regards, Krzysztof