From: Vasileios Amoiridis <vassilisamir@xxxxxxxxx> Remove the IIO specific scaling measurement units from the read functions and add them inside the ->read_raw() function to keep the read_*() generic. This way they can be used in other parts of the driver. Signed-off-by: Vasileios Amoiridis <vassilisamir@xxxxxxxxx> --- drivers/iio/chemical/bme680_core.c | 65 ++++++++++++++++++------------ 1 file changed, 40 insertions(+), 25 deletions(-) diff --git a/drivers/iio/chemical/bme680_core.c b/drivers/iio/chemical/bme680_core.c index 0979c8f0afcf..4669338ec2e5 100644 --- a/drivers/iio/chemical/bme680_core.c +++ b/drivers/iio/chemical/bme680_core.c @@ -661,22 +661,20 @@ static int bme680_gas_config(struct bme680_data *data) return ret; } -static int bme680_read_temp(struct bme680_data *data, int *val) +static int bme680_read_temp(struct bme680_data *data, s16 *comp_temp) { int ret; u32 adc_temp; - s16 comp_temp; ret = bme680_read_temp_adc(data, &adc_temp); if (ret) return ret; - comp_temp = bme680_compensate_temp(data, adc_temp); - *val = comp_temp * 10; /* Centidegrees to millidegrees */ - return IIO_VAL_INT; + *comp_temp = bme680_compensate_temp(data, adc_temp); + return 0; } -static int bme680_read_press(struct bme680_data *data, int *val, int *val2) +static int bme680_read_press(struct bme680_data *data, u32 *comp_press) { int ret; u32 adc_press; @@ -690,15 +688,14 @@ static int bme680_read_press(struct bme680_data *data, int *val, int *val2) if (ret) return ret; - *val = bme680_compensate_press(data, adc_press, t_fine); - *val2 = 1000; - return IIO_VAL_FRACTIONAL; + *comp_press = bme680_compensate_press(data, adc_press, t_fine); + return 0; } -static int bme680_read_humid(struct bme680_data *data, int *val, int *val2) +static int bme680_read_humid(struct bme680_data *data, u32 *comp_humidity) { int ret; - u32 adc_humidity, comp_humidity; + u32 adc_humidity; s32 t_fine; ret = bme680_get_t_fine(data, &t_fine); @@ -709,14 +706,11 @@ static int bme680_read_humid(struct bme680_data *data, int *val, int *val2) if (ret) return ret; - comp_humidity = bme680_compensate_humid(data, adc_humidity, t_fine); - - *val = comp_humidity; - *val2 = 1000; - return IIO_VAL_FRACTIONAL; + *comp_humidity = bme680_compensate_humid(data, adc_humidity, t_fine); + return 0; } -static int bme680_read_gas(struct bme680_data *data, int *val) +static int bme680_read_gas(struct bme680_data *data, int *comp_gas_res) { struct device *dev = regmap_get_device(data->regmap); int ret; @@ -751,9 +745,8 @@ static int bme680_read_gas(struct bme680_data *data, int *val) } gas_range = FIELD_GET(BME680_GAS_RANGE_MASK, gas_regs_val); - - *val = bme680_compensate_gas(data, adc_gas_res, gas_range); - return IIO_VAL_INT; + *comp_gas_res = bme680_compensate_gas(data, adc_gas_res, gas_range); + return 0; } static int __bme680_read_raw(struct iio_dev *indio_dev, @@ -761,7 +754,7 @@ static int __bme680_read_raw(struct iio_dev *indio_dev, int *val, int *val2, long mask) { struct bme680_data *data = iio_priv(indio_dev); - int ret; + int chan_val, ret; guard(mutex)(&data->lock); @@ -777,13 +770,35 @@ static int __bme680_read_raw(struct iio_dev *indio_dev, case IIO_CHAN_INFO_PROCESSED: switch (chan->type) { case IIO_TEMP: - return bme680_read_temp(data, val); + ret = bme680_read_temp(data, (s16 *)&chan_val); + if (ret) + return ret; + + *val = chan_val * 10; + return IIO_VAL_INT; case IIO_PRESSURE: - return bme680_read_press(data, val, val2); + ret = bme680_read_press(data, &chan_val); + if (ret) + return ret; + + *val = chan_val; + *val2 = 1000; + return IIO_VAL_FRACTIONAL; case IIO_HUMIDITYRELATIVE: - return bme680_read_humid(data, val, val2); + ret = bme680_read_humid(data, &chan_val); + if (ret) + return ret; + + *val = chan_val; + *val2 = 1000; + return IIO_VAL_FRACTIONAL; case IIO_RESISTANCE: - return bme680_read_gas(data, val); + ret = bme680_read_gas(data, &chan_val); + if (ret) + return ret; + + *val = chan_val; + return IIO_VAL_INT; default: return -EINVAL; } -- 2.43.0