Use a fallback compatible since for especially for generic defensive setup of parameters, both 6030 and 6032 are the same and U-Boot actually uses a generic 6030/32 function to enable the charger. Signed-off-by: Andreas Kemnade <andreas@xxxxxxxxxxxx> Reviewed-by: Krzysztof Kozlowski <krzysztof.kozlowski@xxxxxxxxxx> --- .../power/supply/ti,twl6030-charger.yaml | 48 +++++++++++++++++++ 1 file changed, 48 insertions(+) create mode 100644 Documentation/devicetree/bindings/power/supply/ti,twl6030-charger.yaml diff --git a/Documentation/devicetree/bindings/power/supply/ti,twl6030-charger.yaml b/Documentation/devicetree/bindings/power/supply/ti,twl6030-charger.yaml new file mode 100644 index 0000000000000..fc604d8a469df --- /dev/null +++ b/Documentation/devicetree/bindings/power/supply/ti,twl6030-charger.yaml @@ -0,0 +1,48 @@ +# SPDX-License-Identifier: GPL-2.0-only OR BSD-2-Clause +%YAML 1.2 +--- +$id: http://devicetree.org/schemas/power/supply/ti,twl6030-charger.yaml# +$schema: http://devicetree.org/meta-schemas/core.yaml# + +title: TWL6030/32 BCI (Battery Charger Interface) + +description: + The battery charger needs to be configured to do any charging besides of + precharging. The GPADC in the PMIC has to be used to get the related + voltages. + +maintainers: + - Andreas Kemnade <andreas@xxxxxxxxxxxx> + +allOf: + - $ref: power-supply.yaml# + +properties: + compatible: + oneOf: + - const: ti,twl6030-charger + - items: + - const: ti,twl6032-charger + - const: ti,twl6030-charger + + interrupts: + items: + - description: Charger Control Interrupt + - description: Charger Fault Interrupt + + io-channels: + items: + - description: VBUS Voltage Channel + + io-channel-names: + items: + - const: vusb + + monitored-battery: true + +required: + - compatible + - interrupts + - monitored-battery + +additionalProperties: false -- 2.39.2