On 29/07/2024 19:47, Artur Weber wrote: > This value was verified by comparing register dumps of the MAX77693 > charger with on mainline with a downstream kernel under Android; the > value on downstream was set to 1.8 amps when charging with a proper > charger. > > Add it to a new battery node and pass it to the MAX77693 charger > so that the fast charge current setting can be used for charging. > > Signed-off-by: Artur Weber <aweber.kernel@xxxxxxxxx> > --- > Changes in v2: > - Switched to monitored-battery > --- Please ping me or resend DTS when the bindings got accepted to power supply tree. Best regards, Krzysztof